Period 4706 Selected Topics (RQ-I-4763) Flashcards

1
Q

When commencing a cooldown shortly after a reactor trip, what actions can be taken to control heatup of the Surge Line?

A

Cooldown results in out surge. Charging flow must be raised to minimize out surge. Also, cooldown rate can be lowered.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

With the Feedwater Heater DCS, what actually causes the Heater Drain Pump ELOs to cycle?

A

With FWH DCS the ELO DOES NOT look at HDP breaker position.

Looks at discharge pressure >350# & flow <2100 gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

SG 21 experienced a 400 GPM SGTR. The crew manually tripped the Reactor, completed E-0 and transitioned to E-3. During E-3, it was found that all SG Stop Valves failed to close. So the crew transitioned to ECA-3.1. When the crew went to start the cooldown, the RO reports that the steam dumps are not operating and the SG PORVs must be used for cooldown. What should the SM primary focus be on at this moment?

A: Do not allow the SG PORV operation since it will alert the neighbors to a problem at the plant
B: Ensure the RO maintains even steaming across all 4 Steam Generators
C: Consult the E-Plan due to potential upgrade criteria being met
D: Tracking maintenance activities to get the SG Stop Valves closed.

A

C: Consult the E-Plan due to potential upgrade criteria being met