Component Cooling Water & Spent Fuel Pit Cooling (RQ-C-4773) Flashcards

1
Q

How does a loss of CCW to the Letdown Hx impact the CVCS system

A
  • QRV-302 will automatically divert to bypass the demineralizers at 143 deg F and rising
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

CRA-415, East CCW Rad monitor is in alarm due to an internal fault. What is the expected response of the CCW system

A
  • CRV-412, CCW surge tank vent valve will close
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

The unit is in mode 6
refueling operations in progress
12-RRC-330, SPENT FUEL PIT AREA RADIATION DETECTOR receives a high radiation alarm.

What is the expected response of the fuel handling ventilation system?

A
  • AFS fans trip
  • AFX goes into Charcoal mode
How well did you know this?
1
Not at all
2
3
4
5
Perfectly