Rapid Load Reduction (AP-25) Flashcards

1
Q

AP-25

What are the entry conditions for a “rapid load reduction”?

A
  • FW heater tube failure
  • T.S. required shutdown
  • turbine runback or programmed ramp
  • GCC called and said so (Path 15)
  • any time plant conditions require > 5 MW/min ramp down
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

AP-25

What ramp rate can DFWCS adequately control SGWL?

If during a rapid load reduction the procedure states turn Pzr heaters on, if the heater are already on, does any action need to be taken?

A

< 225 MW/min

Yes, take control switch to ON, so the heaters stay on

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

AP-25

What are the Programmed Ramps on the turbine?

What are the ramp rates for the Programmed ramps?

A

MFP trip

  • 225 MW/ min -> 650 MW
  • 25 MW/ min -> 550 MW

CWP trip

  • variable rate (Group II Stm Dmps dont open) ->550 MW

HDP

  • 40 MW/ min -> 770 MW
How well did you know this?
1
Not at all
2
3
4
5
Perfectly