What are the different sections of Degraded Condenser?

A

A - loss of condenser vacuum

B - Condenser fouling

C - Traveling screen problem

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What is the maximum condenser pressure allowed before the turbine will trip (AP-7, attch 2)

A
  • full load - 10.2 “ hg abs
  • 600 Mw - 7.2 “ hg abs
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

In AP-7, section A (loss vaccum), what are the Rx trip criteria?

A
  • Pressure above limit (attch 2) and > P-9
  • no CWP
  • abnormal CWP amps (if only one pump on)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

AP-7 (degraded condenser)

In section B (condenser fouling), what are the conditions that warrent ramping the unit to remove affected CWP from service?

A
  • any D/P > 10 psid and rising rapidly
  • all four D/P > 10 psid or approaching, with no change in ocean conditions
  • any D/P approaching 13 psid
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

if dealing with a degraded condensor condition, what is the “caution” asscociated with securing a CWP?

A

the backflow from shutdown of an affected CWP could cause a large rise in loading on the screens of the CWPs still in service. Screens fro the least affected pumps should be in high speed prior to the CWP shutdown.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

AP-7 (section C)

While in traveling screen problems what parameters will direct you to Trip Rx?

A

Screen d/p > 70 “

CWP amps not normal

additional conditions / actions

  • Pwr > 25%
  • trip CWP
  • close MSIV’s
  • adjust 10% stm dmps-> current P s/g
How well did you know this?