AP-11 (CCW malf) Flashcards

1
Q

AP-11

What are the different sections to CCW malfuntions?

A

A - loss of CCW pump/ hi temp

B - CCW in leakage

C - CCW out leakage

D - loss of flow to letdown hx

E - loss of flow to RCP’s

F - loss of surge tank

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

AP-11

What are the various Rx trip criteria in CCW malf:

A: loss CCW pump/hi temp

B: CCW in leakage

A

A

  • no CCW pump available AND
    • no ASW pump available AND
    • CCW temp > 120 deg F

B

  • loose seal inj & CCW to RCPs
  • T Radial Brng > 225 deg F AND
    • T seal out > 235 deg F

C

  • CCW surge tank level out of site low

E

  • CCW flow to RCP lube oil coolers lost for 5 min
How well did you know this?
1
Not at all
2
3
4
5
Perfectly