AP-11 (CCW malf) Flashcards
1
Q
AP-11
What are the different sections to CCW malfuntions?
A
A - loss of CCW pump/ hi temp
B - CCW in leakage
C - CCW out leakage
D - loss of flow to letdown hx
E - loss of flow to RCP’s
F - loss of surge tank
2
Q
AP-11
What are the various Rx trip criteria in CCW malf:
A: loss CCW pump/hi temp
B: CCW in leakage
A
A
- no CCW pump available AND
- no ASW pump available AND
- CCW temp > 120 deg F
B
- loose seal inj & CCW to RCPs
- T Radial Brng > 225 deg F AND
- T seal out > 235 deg F
C
- CCW surge tank level out of site low
E
- CCW flow to RCP lube oil coolers lost for 5 min