AP-4 (loss vital or NV inst AC Flashcards
1
Q
indications for loss of PY-11
A
- Chnl set 1 postage stamps trip (all that de-energize to trip)
- auto makeup unavailable
- LT-112 fails low
- PT-505 fails low
- IR-35 deenergizes
2
Q
indications for loss of PY-12
A
- Chnl set II bistables trip (all that are de-energize to tirp)
- lights for Chnl set III go out
- PT-505 fails low
- PT-506 fails low
- CVCS-8152 fails closed
- FT-128 fails low
3
Q
indications for loss of PY-13
A
- Chnl set III bistables trip (de energ to trip)
- LI-920 fails low (RWST lvl)
- SCMM unnavailable
- LCV-110 and 111 (MDAFW) de-energize
4
Q
indications for loss of PY-14
A
- Chnl set IV bistables trip (de-energ to trip)
- Chnl set I bistable lights go out
- letdown isolates
- N-31 and N-32 energize
- CVCS makeup controller unavailable
5
Q
Indications of Loss of :
PY-11A
PY-13A
PY-15
PY-16
PY-17
A
11A
- Chnl set II bistable lights off
13A
- Chnl set IV bistable lights off
15
- unrelated alarms (TCV’s fail as is)
16
- unrelated alarms ( CCW surge tank LI’s fail low)
17
- generator alarms (valve position for turbine valves indicates trouble)