What are the sections of AP-28 (RCP malfunctions)

A
  • A - RCP hi or lo lube oil level
  • B - RCP seal #1 failure
  • C - RCP seal #2 or #3 failure
  • D - loss of seal injection
  • E - loss of CCW to RCP / or RCP hi temp
  • F - loss of seal inj AND loss of therm barr cooling
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What actions does FOP criteria for AP-28 (RCP malf) have you take?

What are the criteria that make you take actions?

A

1 seal outlet > 235 F

Trip reactor, implement E-0, stop affected RCP, go to step….

Seal return flow > 6 gpm and pump brng temps rising

Seal return flow > 6 gpm and seal return temps rising

Seal return flow > 8 gpm

Seal return flow < 0.8 gpm and pump brng temps rising

Seal return flow < 0.8 gpm and seal return temps rising

Any motor brng temp > 200 F

Any motor Stator temp > 300 F

CCW temp > 120 F

loss CCW to RCP motor coolers > 5 min

radial brng outlet > 225 F

loss of seal inj and thermal barier cooling

any valid seal flow or bearing temp alarm concurrent with vibration alarm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

In AP-28 (RCP malfunction) what are the generic actions taken if procedure directs you to trip Rx and trip RCPs for seal #1 failure?

A

Trip Rx

Trip affected RCPs

Close seal #1 outlet (w/in 3-5 min)

close associated spray valve (if applicable)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

AP-28

In section A (RCP Hi or Lo lube oil level) What condition meets Rx trip criteria?

A
  • Bearing temp > 200 F
  • valid RCP vibration alarm
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

AP-28

What does the Total #1 Seal Leakoff consist of?

If input for #2 seal leakoff flow Hi is not in …..what can we assume?

A
  • sum of #1 and #2 seal leakoff indications
  • # 2 seal leakoff is < 0.75 gpm
How well did you know this?
1
Not at all
2
3
4
5
Perfectly