AP-6

What are the two mechanisms (flow and concentration) that describe “emergency boration”?

What is thumbrule that equates to gallons of boric acid added to change [B] ppm?

A

>/= 30 gpm of 7000-7700 ppm [B]

> 90 gpm of 2300-2500 ppm [B]

9 gal/ ppm (for BAST)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

AP-6

what are the four methods (in preferred order) to emergency borate?

A
  • Normal Boration via M/U control system
  • open CVCS-8104 (Emergency Borate Valve)
  • Swap charging suction to RWST (90 gpm)
  • Locally open CVCS-8471 (manual emergency borate valve)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

AP-6

what are the entry conditions for Emergency Boration?

A
  • Control rods below RIL (when critical)
  • two or more rods fail to insert on Rx trip
  • uncontrolled c/d on Rx trip (no ESFAS actuation)
  • boration required and normal method (via VCT) not avail
  • loss of SDM
  • uncontrolled/ unexplained reactivity rise
    • control rod insertion
    • Tave or Power rise (w/no rise in STM Dmd
    • rise in counts (when shut down)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

AP-6

If the rx trips and you have 3 stuck rods, how much are you required to borate?

If a load rejection caused rods to step in past RIL Lo-Lo alarm, how long do you have to initiate emergency boration?

A

400 ppm / stuck rod (1200 ppm)

or

2000 - 2400 ppm

whichever is less