AP-30 (Mn. Gen Malf) Flashcards

1
Q

AP-30 (Mn Gen Malf)

Per FOP what is the Unit trip criteria?

A

Bottom or Top stator coil delta T > 21 F

individual stator T/C > 193 F

GCM alarm w/

  • stator temp alarm
  • exciter ground alarm
  • turb gen vib
  • RF alarm

RF alarm w/

  • stator temp alarm
  • exciter ground alarm
  • turb gen vib or rise in temp
  • GCM alarm

Generator voltage unstable and cannot be controlled

Seal oil cooler outlet temp > 125 deg F for 15 min

Gen H2 pressure lowering uncontrollably

Gen liquid level high and Defoaming tnk level high

H2 / seal oil DP not kept > 3 psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

(AP-30 Mn Gen Malf)

What are the sections to AP-30?

A

A - Generator Condition Monitor

B - Exciter Ground

C - Exciter Trouble

D - Generator Trouble

E - Generator Seal Oil Trouble

F - Generator H2 system Trouble

G - Stator wtr cooling system Trouble

How well did you know this?
1
Not at all
2
3
4
5
Perfectly