LOT 203.11 LWPS Flashcards
- LOT 203.11 LWPS*
- *
The Spent Resin Processing subsystem consists of a High Activity and a Low Activity Spent Resin storage system. What plant demins does each accomodate?
- High Activity:*
- *CVCS Mixed Beds / Cation Bed**
- *Recycle Evaporate Feed Demins**
- *Concentrated Boric Acid Demins**
- *S/G B/D Demins**
- Low Activity:*
- *Boron Thermal Regen Demins**
- *SFP Demins**
- *Recycle Evaporator Condensate Demins**
- Note:*
- The purpose is to transfer resin w/o generating a lot of liquid waste and to provide decay time before resin is transported offsite for burial.*
- LOT 203.11 LWPS*
- *
What are the three methods for processing liquid waste?
- *Filtration**
- WHT (52’ MAB)*
- Laundry Hot Shower Tank (10’ MAB) [Dummy]*
- FDT(52’ MAB) [Dummy]*
- Condensate Polishing Waste Collection Tank (52’ MAB) [Dummy]*
- *Demins**
- WHT Purification Demin (52’ MAB)*
- LWPS Aux Demin (52’ MAB)*
- Waste Evaporator Condensate Demin (52’ MAB)*
- *Evaporation**
- Not Used at STP*
- LOT 203.11 LWPS*
- *
What water sources drain into the WHT?
- Normal:*
- *Primary Sample Drains**
- 100 gpd*
- *MAB Gravity Drains**
- Filters / Demins*
- Alternate:*
- *RCDT**
- *Containment Normal Sump**
WHT should only be going up ≈ 100 gpd.
- LOT 203.11 LWPS*
- *
Where are the tanks in the LWPS physically located?
- 10’ MAB South Wall:*
- *Laundry/Hot Shower Tank (1)**
- *FDT (1)**
- *CPRWCT (1)**
- *WHT (1)**
- *Waste Evaporator Condensate Tanks (2)**
- Not Used*
- *WMTs A/B/C**
- Vented to their room*
- Outside MAB South End:*
- *WMT D/E/F**
- 4’ FHB:*
- *LWPS Surge Tanks (2)**
- Vented to their room*
Pumps are located in areas around tanks
- Note:*
- Most tanks in the LWPS including WMT D/E/F are vented plant vent header.*
- LOT 203.11 LWPS*
- *
What system does the LWPS use to discharge water?
OLACW
CWS
Activity - High on RT-8038 will terminate discharge (FV-4077) and send water back to respective WMT. (Long path recirc)
- LOT 203.11 LWPS*
- *
What is the difference between an influent tank and an effluent tank?
- Influent Tank:*
- *Receive waste from system and store it until processed**
- WHT, LHST, CPRWCT, FDT, Surge Tanks (2)*
- Effluent Tank:*
- *Receive processed liquids and store it until released/recycled**
- WMTs (6)*
- LOT 203.11 LWPS*
- *
What is the function of the WHT?
Collects Reactor Grade leakage and other tritiated and aerated water sources
- Note:*
- Non-Reactor Grade water goes to Condensate Polishing Regeneration Waste Collection Tank (George Tank)*
- LOT 203.11 LWPS*
- *
For an unprotected outdoor tank, what is activity limited to? (LCO 3.11.1 Liquid Holdup Tanks)
- *≤ 10 Curies**
- Excludes Tritium and entrained Noble Gases*
LCO N/A to WMT D/E/F b/c they have a berm.
Used for temporary tanks.
- LOT 203.11 LWPS*
- *
Where does each tank in the LWPS get pumped to?
- WHT:*
- *FDT (CPRWCT)**
- Uses Demins/Filters*
- CPRWCT:*
- *FDT**
- Only Strainers*
- Surge Tanks:*
- *FDT (CPRWCT)**
- Only Strainers*
- LHST:*
- *WMT C**
- Only Strainers*
- FDT:*
- *WMT D/E/F**
- Strainers / ALPS*
- RHTs:*
- *WMT D/E/F**
- ALPS*