LOT 201.10 ECCS Flashcards
- LOT 201.10 ECCS*
- *
What are the Emergency Core Cooling System (ECCS) acceptance criteria?
Coolable Geometry
Long-Term cooling
Cladding Oxidation
≤ 17% the total cladding thickness before oxidation.
- *Peak Cladding Temperature**
- ≤ 2200 ˚F*
- *H2 Generation**
- ≤ 1% the total amount of H2 produced from all metal surrounding the fuel reacting*
- (excludes metal around plenum volume)*
DBAs:
- LOCA
- SLB
- Fuel Handling Accident
- LOT 201.10 ECCS*
- *
What fills/drains the accumulators?
# *_Fill:_* HHSI
- Drain:*
- *RWST**
- *RCDT (Spoolpiece)**
- Complete Draining*
- *Primary Sampling**
- LOT 201.10 ECCS*
- *
In order for the RWST to be OPERABLE in MODES 1 - 4, what must water volume and boron concentration be?
≥ 458,000 gallons
2800 ppm - 3000 ppm
LCO 3.5.5 RWST
Applicable: MODES 1 - 4
- LOT 201.10 ECCS*
- *
In order for the accumulators to be OPERABLE in MODES 1 - 3 w/ PZR pressure > 1000 psig, what must water volume and boron concentration be?
- Water Volume:*
- *8800 gal - 9100 gal**
- Boron Concentration:*
- *2700 ppm - 3000 ppm**
LCO 3.5.1 Accumulators
Applicable: MODES 1 - 3
- LOT 201.10 ECCS*
- *
What valves in the ECCS have a power lockout feature?
- *HHSI/LHSI Hot leg injection valves (MOV-008/MOV-019)**
- 100% Power: Closed w/ power locked out*
- CP-001*
- *Accumulator outlet valves (MOV-039)**
- 100% Power: Open w/ power locked out*
- CP-001 / ASP*
No accumulator pressure / level indicators exist on ASP!!
- Note:*
- 2 transfer switches for accumulator outlet valves. 1 transfers control and VPI and the other transfers power lockout feature.*
- LOT 201.10 ECCS*
- *
What will auto open the accumulator discharge valve? (MOV-039)
SI
- *RCS Pressure ≥ P-11**
- PZR Pressure ≥ 1985 psig [2/3]*
- LOT 201.10 ECCS*
- *
How do you place ECCS in-service during a plant heatup from cold shutdown?
- Mode 5:*
- *ALL HHSI pumps inoperable**
- *SI not blocked**
- Before Entering MODE 4:*
- *Open ALL HHSI CL injection valves**
- *2 trains of LHSI OPERABLE**
- Within 4 hrs of going > 200 ˚F and before exceeding 225 ˚F:*
- *1 HHSI OPERABLE and 1 HHSI in Standby**
- Before Entering MODE 3 (350 ˚F):*
- *ALL LHSI OPERABLE**
- Within 4 hrs of going > 350 ˚F and before exceeding 375 ˚F:*
- *ALL HHSI OPERABLE**
- 900 psig - 1000 psig:*
- *ALL Acummulators OPERABLE**
- LOT 201.10 ECCS*
- *
At what RCS pressures will the ECCS Accumulators, HHSI pumps, and LHSI pumps inject into the RCS Cold Legs?
- HHSI:*
- *< 1600 psig**
- Accumulators:*
- *590 - 670 psig**
- LHSI:*
- *< 300 psig**
Receive water from RWST.
- Note:*
- During DBA, Accumulators will inject 1st.*
- LOT 201.10 ECCS*
- *
Where does HHSI and LHSI mini-flow valves discharge to?
RWST
Close on SI auto recirculation signal
- LOT 201.10 ECCS*
- *
Which valves will not be able to be manually opened if the respective train’s Emergency Sump Outlet Valve (MOV-016) is open?
HHSI Mini-Flow Valves (MOV-011/MOV-012)
LHSI Mini-Flow Valves (MOV-013/MOV-014)
RWST Outlet Valves (MOV-001)
To manually open Emergency Sump Outlet Valve:
- RWST Outlet Valve closed (Manual Only)
- HHSI Mini-Flow Valve closed [1/2]
- LHSI Mini-Flow Valve closed [1/2]
- LOT 201.10 ECCS*
- *
What are the four phases of a DBA LOCA?
- *Blowdown**
- Begins with LOCA and ends with RCS pressure = CTMT pressure*
- *Refill**
- Water at bottom of the reactor vessel and reaches the bottom of the fuel rods via addition of ECCS (Accumulators and SI pumps).*
- *Reflood**
- Rx vessel filled with water*
- Core temperature rise has terminated*
- Core temperatures have been reduced to their long term steady state level.*
- *Long Term Recirculation**
- Cold Leg Recirc (1st Phase)*
- Hot Leg Recirc (2nd Phase)*
- Hot Leg Recirc starts 5.5 hrs (Operator Action) after start of LOCA and cools upper head and prevents boron precipitation.*
- LOT 201.10 ECCS*
- *
What is the system lineup during hot leg recirc?
2 ECCS trains injecting into Hot Legs
1 ECCS train injecting into Cold Leg
LHSI and HHSI mini-flow valves closed
Taking Suction from Emergency Sumps
HHSI and LHSI are operated together. Never align HHSI to Hot leg and LHSI to Cold leg or vice versa.
- Note:*
- Cold Leg Recirc is the exact same except all 3 ECCS trains injecting into cold legs.*
- LOT 201.10 ECCS*
- *
What will cause an SI auto recirculation signal?
SI Signal
AND
- *RWST Level - Low 2 (≤ 75,000 gal) [1/1]**
- Each lvl switch provides signal for it’s train only*
Closes HHSI AND LHSI pump mini-flow valves.
When ≥ 1 valve for each pump closed:
- Opens containment sump → SI suction header Isolation valve.
RWST → SI suction header isolation valve must be manually closed by operator. (CP001)
- Note:*
- Reset and RWST lvl indication are located on CP001*
- LOT 201.10 ECCS*
- *
What cools the HHSI/LHSI upper and lower bearings?
Resevoir Oil Baths
- LOT 201.10 ECCS*
- *
When must all HHSI pumps be inoperable per tech specs?
- *MODE 5**
- *MODE 6 w/ Rx Vessel Head on**
LCO 3.5.3.2 ECCS Subsytems - Tavg ≤ 200 ˚F