LOT 201.09 RHR Flashcards
- LOT 201.09 RHR*
- *
What is the RCS C/D rate using RHR?
Assumption:
- CCW → RHR HX: 105 ˚F
- C/D started 4 hrs after Rx S/D
- 3 Trains:*
- *350 ˚F - 212 ˚F: 7 hrs**
- *350 ˚F - 150 ˚F: 12 hrs**
- 2 Trains:*
- *350 ˚F - 200 ˚F: 9 hrs**
- 1 Train:*
- *350 ˚F - 200 ˚F: 19 hrs**
Note:
During initital C/D, CCW intlet → RHR HX allowed to ↑ 120 ˚F for a max of 4 Hrs.
- LOT 201.09 RHR*
- *
What RHR components/indications are there on the ASP?
- *RHR Pump Suction Isolations**
- (MOV-060/MOV-061)*
- *RHR HX TCVs**
- (HCV-0864/0865/0866)*
- Loss of 7300 cabinet auto switches control to ASP*
- *RHR HX Bypass Flow (Manual Control)**
- (FCV-0851/0852/0853)*
- Loss of 7300 cabinet auto switches control to ASP*
RHR HX Flow
RHR HX Temp
- LOT 201.09 RHR*
- *
Which RHR trains are used to transfer refueling water from the refueling cavity to the RWST at the end of a refueling operation?
RHR Train “B”
RHR Train “C”
Flow is controlled by throttling the respective train IRC or ORC isolation valve to the RWST
Note:
Do not use train that is selected for shutdown cooling.
- LOT 201.09 RHR*
- *
What cools the RHR pump seals?
CCW
RHR pump may be ran w/o CCW if RCS Temp < 120 ˚F.
- LOT 201.09 RHR*
- *
What happens in the RHR system during a SI?
RHR HX Bypass Closes
RHR HX TCV Valve Full Open
RHR Pumps Trip
- *CCW from RHR HX opens**
- CCW pump mini-flow concerns*
- LOT 201.09 RHR*
- *
What trips the RHR pumps?
SI
RHR Flow - Low (925 gpm [5 sec TC])
CP001 Indications:
- Amps
- Flow
- LOT 201.09 RHR*
- *
When is RHR placed in service?
≤ 350 ˚F
- *≤ 332 psig**
- Interlock to open MOV-060/MOV-061*
No auto close features for MOV-060/MOV-061.
- LOT 201.09 RHR*
- *
Which pressure transmitters provide the open permissive for the RHR Suction Valves? (MOV-060/MOV-061)
- RHR Train “A”:*
- *MOV-060A: PT-405**
- *MOV-061A: PT-406**
- RHR Train “B”:*
- *MOV-060B: PT-406**
- *MOV-061B: PT-407**
- RHR Train “C”:*
- *MOV-060C: PT-407**
- *MOV-061C: PT-405**
Power Supplies:
- PT-405: Train “A”
- PT-406: Train “B”
- PT-407: Train “C”
- LOT 201.09 RHR*
- *
What keeps the RHR HX full of water?
RCP Seal Standpipe
RMW Makeup
RCP Makeup Line Pressure - Low (17 psig) will cause “RHR HX NOT FULL” alarm on CP001.
Note:
No actual level indication just makeup line pressure.
- LOT 201.09 RHR*
- *
Where in the CVCS does RHR enter and exit?
- Supply:*
- *Downstream of Regen HX (IRC)**
- RHR Train “A” AND Train “B”*
- Return:*
- *Upstream of VCT**
- RHR Train “A” ONLY*
Low Pressure Letdown:
- All letdown orifices open
- RHR pump not required to be running
- PCV-135 able to maintain ≈ 380 psig