LOT 201.09 RHR Flashcards

1
Q
  • LOT 201.09 RHR*
    • *

What is the RCS C/D rate using RHR?

A

Assumption:

  • CCW → RHR HX: 105 ˚F
  • C/D started 4 hrs after Rx S/D
  • 3 Trains:*
  • *350 ˚F - 212 ˚F: 7 hrs**
  • *350 ˚F - 150 ˚F: 12 hrs**
  • 2 Trains:*
  • *350 ˚F - 200 ˚F: 9 hrs**
  • 1 Train:*
  • *350 ˚F - 200 ˚F: 19 hrs**

Note:
During initital C/D, CCW intlet → RHR HX allowed to ↑ 120 ˚F for a max of 4 Hrs.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q
  • LOT 201.09 RHR*
    • *

What RHR components/indications are there on the ASP?

A
  • *RHR Pump Suction Isolations**
  • (MOV-060/MOV-061)*
  • *RHR HX TCVs**
  • (HCV-0864/0865/0866)*
  • Loss of 7300 cabinet auto switches control to ASP*
  • *RHR HX Bypass Flow (Manual Control)**
  • (FCV-0851/0852/0853)*
  • Loss of 7300 cabinet auto switches control to ASP*

RHR HX Flow

RHR HX Temp

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q
  • LOT 201.09 RHR*
    • *

Which RHR trains are used to transfer refueling water from the refueling cavity to the RWST at the end of a refueling operation?

A

RHR Train “B”

RHR Train “C”

Flow is controlled by throttling the respective train IRC or ORC isolation valve to the RWST

Note:
Do not use train that is selected for shutdown cooling.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q
  • LOT 201.09 RHR*
    • *

What cools the RHR pump seals?

A

CCW

RHR pump may be ran w/o CCW if RCS Temp < 120 ˚F.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q
  • LOT 201.09 RHR*
    • *

What happens in the RHR system during a SI?

A

RHR HX Bypass Closes

RHR HX TCV Valve Full Open

RHR Pumps Trip

  • *CCW from RHR HX opens**
  • CCW pump mini-flow concerns*
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q
  • LOT 201.09 RHR*
    • *

What trips the RHR pumps?

A

SI

RHR Flow - Low (925 gpm [5 sec TC])

CP001 Indications:

  • Amps
  • Flow
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q
  • LOT 201.09 RHR*
    • *

When is RHR placed in service?

A

≤ 350 ˚F

  • *≤ 332 psig**
  • Interlock to open MOV-060/MOV-061*

No auto close features for MOV-060/MOV-061.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q
  • LOT 201.09 RHR*
    • *

Which pressure transmitters provide the open permissive for the RHR Suction Valves? (MOV-060/MOV-061)

A
  • RHR Train “A”:*
  • *MOV-060A: PT-405**
  • *MOV-061A: PT-406**
  • RHR Train “B”:*
  • *MOV-060B: PT-406**
  • *MOV-061B: PT-407**
  • RHR Train “C”:*
  • *MOV-060C: PT-407**
  • *MOV-061C: PT-405**

Power Supplies:

  • PT-405: Train “A”
  • PT-406: Train “B”
  • PT-407: Train “C”
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q
  • LOT 201.09 RHR*
    • *

What keeps the RHR HX full of water?

A

RCP Seal Standpipe

RMW Makeup

RCP Makeup Line Pressure - Low (17 psig) will cause “RHR HX NOT FULL” alarm on CP001.

Note:
No actual level indication just makeup line pressure.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q
  • LOT 201.09 RHR*
    • *

Where in the CVCS does RHR enter and exit?

A
  • Supply:*
  • *Downstream of Regen HX (IRC)**
  • RHR Train “A” AND Train “B”*
  • Return:*
  • *Upstream of VCT**
  • RHR Train “A” ONLY*

Low Pressure Letdown:

  • All letdown orifices open
  • RHR pump not required to be running
  • PCV-135 able to maintain ≈ 380 psig