LOT 201.12 CCW Flashcards
- LOT 201.12 CCW*
- *
What systems operate at a higher pressure than CCW?
- *RHR HX**
- *RCP Thermal Barrier**
- *Letdown HX**
- *Excess Letdown HX**
- *RCDT HX**
- *Primary Sample Coolers**
- *SFP HX**
- LOT 201.12 CCW*
- *
What is the temperature band CCW operates in during normal operations?
- *60 ˚F - 105 ˚F**
- MAX DBA: 122.3 ˚F*
60 ˚F Basis:
- Prevents condensate in Lube Oil Coolers
- Prevents thermal shock to RCP thermal barrier
- Note:*
- During C/D CCW Temp may reach 120 ˚F for 4 hrs (RHR cooling req.)*
- LOT 201.12 CCW*
- *
What CCW loads isolate when the CCW Surge tank reaches 64.6%? (1st Low Level Isolation)
- HXs:*
- *Letdown HX**
- *Excess Letdown HX**
- *RCDT HX**
- Evaporators:*
- *Boron Recycle Evaporator**
- *LWPS Evaporator**
- Sample Coolers:*
- *Boric Acid Sample Cooler**
- *Primary Sample Coolers**
- Radiation Monitors:*
- *S/G Blowdown Rad Monitor**
- *BRS Rad Monitor**
- LOT 201.12 CCW*
- *
What are the important levels in the CCW Surge Tank?
- 83.3%:*
- *High Alarm**
- 74%:*
- *Makeup Valve Closes**
- 68.75%:*
- *Makeup Valve Opens**
- 66.7%:*
- *Low Alarm**
- 64.6%:*
- *1st Low Level Isolation**
- 61.5%:*
- *2nd Low Level Isolation**
- 56%:*
- *Baffles Begin**
- 49%:*
- *Compartment Level - Low Alarm**
- 8.3%:*
- *Compartment Level - Low 2 Alarm**
- Demin water normally fills CCW Surge Tank. (Auto)
- RMWST can fill the CCW Surge Tank. (Manual)
- LOT 201.12 CCW*
- *
What will happen in the CCW system during a SI?
- *All 3 CCW pumps start**
- 20 Sec on ESF DG Sequencer*
- Will start even if switches on CP001/CP002 are in off*
- *Opens CCW HX outlet and closes bypass valves**
- Full flow through HX*
Isolates non-ESF loads
- *Aligns CCW to RCFCs**
- Secures RCB Chill Water*
- *Opens RHR HX outlet valves**
- CCW Min Flow requirements*
- Note:*
- Must re-align cooling to SFP HXs in 2.5 hrs.*
- LOT 201.12 CCW*
- *
What will cause the thermal barrier isolation valve to shut?
CCW Flow - High (60 gpm)
CCW Temp - High (187 ˚F)
Protects CCW piping from thermal barrier HX leak.
Switches located on CP004.
Two in-line backpressure sensing valves provide backup
- Start to close at 120 psig
- Full close at 150 psig
- Note:*
- Backpressure sensing valves auto-reset when pressure drops below setpoint*
- LOT 201.12 CCW*
- *
What happens to the CCW system during a LOOP?
- *RHR HX Outlet Valve opens**
- *DWS Makeup to CCW Surge tank closes**
- *RCB Chilled Water Isolates to RCFCs**
- *RCDT HX Isolates**
- *Train “B” / Train “C” CCP X-Conn Closes**
- Supply and Return*
- *One CCW return header isolation closes**
- LOT 201.12 CCW*
- *
What will happen in the CCW system when the CCW Surge tank reaches 61.5%? (2nd Low Level Isolation)
- *Isolates CCW Header**
- Isolates RCP Upper/Lower Bearing Coolers, Thermal Barrier, RCP Motor Air Coolers, SFP HX, PASS Coolers*
CCW Train “B” → CCP “B” and Seal Water HX
CCW Train “C” → CCP “A” and PDP
- *Opens RHR Outlet Valves for running CCW Pumps ONLY**
- Min flow requirements*
- Note:*
- As soon as CCW common header isolated, standby CCW pump will start on CCW Header Pressure - Low (76 psig)*
- LOT 201.12 CCW*
- *
Where are the CCW components physically located?
- 60’ MAB:*
- *Surge Tank**
- *Chemical Addition Tank**
- 29’ MAB:*
- *HXs**
- 10’ MAB:*
- *CCW Pumps**