LOT 201.12 CCW Flashcards

1
Q
  • LOT 201.12 CCW*
    • *

What systems operate at a higher pressure than CCW?

A
  • *RHR HX**
  • *RCP Thermal Barrier**
  • *Letdown HX**
  • *Excess Letdown HX**
  • *RCDT HX**
  • *Primary Sample Coolers**
  • *SFP HX**
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q
  • LOT 201.12 CCW*
    • *

What is the temperature band CCW operates in during normal operations?

A
  • *60 ˚F - 105 ˚F**
  • MAX DBA: 122.3 ˚F*

60 ˚F Basis:

  • Prevents condensate in Lube Oil Coolers
  • Prevents thermal shock to RCP thermal barrier
  • Note:*
  • During C/D CCW Temp may reach 120 ˚F for 4 hrs (RHR cooling req.)*
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q
  • LOT 201.12 CCW*
    • *

What CCW loads isolate when the CCW Surge tank reaches 64.6%? (1st Low Level Isolation)

A
  • HXs:*
  • *Letdown HX**
  • *Excess Letdown HX**
  • *RCDT HX**
  • Evaporators:*
  • *Boron Recycle Evaporator**
  • *LWPS Evaporator**
  • Sample Coolers:*
  • *Boric Acid Sample Cooler**
  • *Primary Sample Coolers**
  • Radiation Monitors:*
  • *S/G Blowdown Rad Monitor**
  • *BRS Rad Monitor**
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q
  • LOT 201.12 CCW*
    • *

What are the important levels in the CCW Surge Tank?

A
  • 83.3%:*
  • *High Alarm**
  • 74%:*
  • *Makeup Valve Closes**
  • 68.75%:*
  • *Makeup Valve Opens**
  • 66.7%:*
  • *Low Alarm**
  • 64.6%:*
  • *1st Low Level Isolation**
  • 61.5%:*
  • *2nd Low Level Isolation**
  • 56%:*
  • *Baffles Begin**
  • 49%:*
  • *Compartment Level - Low Alarm**
  • 8.3%:*
  • *Compartment Level - Low 2 Alarm**
  • Demin water normally fills CCW Surge Tank. (Auto)
  • RMWST can fill the CCW Surge Tank. (Manual)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q
  • LOT 201.12 CCW*
    • *

What will happen in the CCW system during a SI?

A
  • *All 3 CCW pumps start**
  • 20 Sec on ESF DG Sequencer*
  • Will start even if switches on CP001/CP002 are in off*
  • *Opens CCW HX outlet and closes bypass valves**
  • Full flow through HX*

Isolates non-ESF loads

  • *Aligns CCW to RCFCs**
  • Secures RCB Chill Water*
  • *Opens RHR HX outlet valves**
  • CCW Min Flow requirements*
  • Note:*
  • Must re-align cooling to SFP HXs in 2.5 hrs.*
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q
  • LOT 201.12 CCW*
    • *

What will cause the thermal barrier isolation valve to shut?

A

CCW Flow - High (60 gpm)

CCW Temp - High (187 ˚F)

Protects CCW piping from thermal barrier HX leak.

Switches located on CP004.

Two in-line backpressure sensing valves provide backup

  • Start to close at 120 psig
  • Full close at 150 psig
  • Note:*
  • Backpressure sensing valves auto-reset when pressure drops below setpoint*
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q
  • LOT 201.12 CCW*
    • *

What happens to the CCW system during a LOOP?

A
  • *RHR HX Outlet Valve opens**
  • *DWS Makeup to CCW Surge tank closes**
  • *RCB Chilled Water Isolates to RCFCs**
  • *RCDT HX Isolates**
  • *Train “B” / Train “C” CCP X-Conn Closes**
  • Supply and Return*
  • *One CCW return header isolation closes**
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q
  • LOT 201.12 CCW*
    • *

What will happen in the CCW system when the CCW Surge tank reaches 61.5%? (2nd Low Level Isolation)

A
  • *Isolates CCW Header**
  • Isolates RCP Upper/Lower Bearing Coolers, Thermal Barrier, RCP Motor Air Coolers, SFP HX, PASS Coolers*

CCW Train “B” → CCP “B” and Seal Water HX

CCW Train “C” → CCP “A” and PDP

  • *Opens RHR Outlet Valves for running CCW Pumps ONLY**
  • Min flow requirements*
  • Note:*
  • As soon as CCW common header isolated, standby CCW pump will start on CCW Header Pressure - Low (76 psig)*
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q
  • LOT 201.12 CCW*
    • *

Where are the CCW components physically located?

A
  • 60’ MAB:*
  • *Surge Tank**
  • *Chemical Addition Tank**
  • 29’ MAB:*
  • *HXs**
  • 10’ MAB:*
  • *CCW Pumps**
How well did you know this?
1
Not at all
2
3
4
5
Perfectly