LOT 201.07 Rx Makeup System Flashcards
- LOT 201.07 Rx Makeup System*
- *
What will auto start/ stop the BAT pumps?
- Auto Start:*
- *VCT Level (28%)**
- 200 gpm blend flow (RMWST/BAT)*
- *Manual / Borate Initiated**
- Manual: 200 gpm blend flow (RMWST/BAT)*
- Borate: Flowrate (User Defined 0-100 gpm)*
- Auto Stop:*
- *VCT Level (48%)**
- Trip:*
- *Overload**
Can be controlled from ASP.
- Note:*
- Unlike RMW pumps that trip on low level, the BAT pumps have no low level trip.*
- LOT 201.07 Rx Makeup System*
- *
What is the usable volume and the boric acid concentration of the BATs?
- Usable Volume:*
- *33,500 gal/tank**
- 2 tanks*
- Boron Concentration:*
- *7000 - 7700 ppm**
MODES 1 - 6:
- ≥ 27,000 gal (MODES 1 - 4)
- ≥ 3,200 gal (MODES 5 - 6)
- ≥ 7000 ppm
- ≥ 65 ˚F
CP004:
- Level and temperature indication
- LOT 201.07 Rx Makeup System*
- *
What are the different ways an operator can inject boron into the RCS?
- BAT:*
- *Charging Line**
- Normal / Alt. Immediate: Flow limited by FCV-0110A (0-100 gpm)*
- Emergency: BAT pump flowrate (125 gpm)*
- *RCP Seal Injection**
- 5 gal/min per pump*
- *Gravity Feed**
- CV-0333 / CV-0226*
- RWST:*
- *Charging Line**
- MOV-112C / MOV-113B*
- BTRS:*
- *Demins**
The emergency boration path through the charging line, the gravity feed path, and the RWST path are all considered “Emergency Boration.”
- Note:*
- VCT Level - Low 2 (3%) will close MOV-112B/MOV-113A and prevent normal boration.*
- LOT 201.07 Rx Makeup System*
- *
Where is the water injected into the CVCS during alt. dilute?
Some goes to VCT inlet
Some goes to CCP suction
Advantage:
- Reduces delay in diluting the RCS
Disadvantage:
- Some of water will bypass VCT and will not absorb H2
- *
- Note:*
- During dilute mode, all flow goes into VCT inlet.*
- LOT 201.07 Rx Makeup System*
- *
What happens during the different level setpoints in the RMWST?
- 97%:*
- *Tank Overfills**
- 92.8%:*
- *Close DWS Makeup Valve (LV-7651)**
- 57.3%:*
- *Open DWS Makeup Valve (LV-7651)**
- 54%:*
- *Closes Non-Essential Isolation Valves (FV-7659/FV-7663)**
- *Closes Sample Valve (FV-7664)**
- *Level - Low Alarm**
- 5.6%:*
- *Trips Rx Makeup Pumps**
CP004 Alarms:
- Level - High 2 Alarm (96.4%)
- Level - High Alarm (94.7%)
- Level - Low Alarm (54%)
- Level - Low 2 Alarm (6%)
- LOT 201.07 Rx Makeup System*
- *
What does the RMWST supply water to?
- *RCS**
- *CCW Surge Tank**
- Alternate*
- *SFP**
- Makeup for evaporation*
- *RWST**
- Blended flow of boric acid and RMWST*
- *BRS Cond Demin**
- RMWST Purification*
- *BA Batching Tank**
- *PRT**
- Feed and Bleed (Alternate)*
- *RCP seal leak off stand pipes**
- *BTRS Demineralizers**
- Demin Flushing*
- LOT 201.07 Rx Makeup System*
- *
What are the Boration thumb rules?
DBW = 10 pcm/ppm
10 gals of boron/ppm
- LOT 201.07 Rx Makeup System*
- *
What powers the RMW pumps, BAT pumps, and CCPs?
- RMW Pump A:*
- *MCC E1C2**
- RMW Pump B:*
- *MCC E1B4**
- BAT Pump A:*
- *MCC E1C4**
- BAT Pump B:*
- *MCC E1A4**
- CCP A:*
- *E1C**
- CCP B:*
- *E1A**
C-B-C-A-C-A (2444)
- LOT 201.07 Rx Makeup System*
- *
How do you calculate the boron blender potentiometer setting?
FK-0110 Setpoint
20 x Boron Concentration of RCS/Boric Concentration of BAT
Controller set up for 0-10 setting. Correlates to 0-100 gpm. (5 setting is 50 gpm)
- LOT 201.07 Rx Makeup System*
- *
What plant conditions require emergency boration?
Loss of SDM
Reactivity excursion that normal means cannot handle
CRDM below insertion limits
> 1 Control not inserting on Rx Trip
Loss of DRPI after Rx Trip
ATWS
QDPS S/D Monitor Alarm
- LOT 201.07 Rx Makeup System*
- *
What will make the makeup stop valves (FCV-0110B/FCV-0111B) auto close?
- Total Makeup Flow Deviation:*
- *± 15 gpm [15 sec TC]**
- BA Flow to Blender Deviation:*
- *± 2 gpm [15 sec TC]**
- LOT 201.07 Rx Makeup System*
- *
How long will it take to go from 100% RTP to 1% RTP with 1 BAT pump and no rod motion?
< 90 mins
In an additional 90 mins, enough boric acid can be injected to compensate for Xe decay.
- LOT 201.07 Rx Makeup System*
- *
What will auto close the boric acid purification loop isolation valves? (FV-8400A/B)
BAT Tank Level - Low (29,584 gal) [1/1 on 1/2]
Level Recorder located on CP018.
Control switches for FV-8400A/B located on CP004.
- Note:*
- This is the only BAT tank level actuation. The BAT pumps will NOT trip on a low level actuation.*
- LOT 201.07 Rx Makeup System*
- *
What will auto close the RMW non-essential service isolation valves? (FV-7663/FV-7659)
- *SI**
- SI Train “B” (FV-7663)*
- SI Train “C” (FV-7659)*
RMWST Level (54%)
RMWST Level (54%) will also isolate the RMWST sample line (FV-7664). (SI will not)
- Note:*
- Makeup to CCW surge tank and SFP will NOT be secured.*
- LOT 201.07 Rx Makeup System*
- *
What is the useable capacity of the RMWST?
153,050 gal
Actual Capacity: 160,000 gal
- Note:*
- Level indication on CP004. (Tank overfills at 97%)*