LOT 202.27 Aux Steam Flashcards
1
Q
- LOT 202.27 ASS*
- *
What loads does the ASS supply?
A
- *Gland Seal Steam**
- When MSS < 185 psig*
Deaerator Pegging Steam
Boric Acid Batch Tank
2
Q
- LOT 202.27 ASS*
- *
What will auto shut aux steam to MAB isolation valves? (FV-8838A/B)
A
- HELBA Protection:*
- *Room Temperature - High (112.7 ˚F)**
- *Aux Steam Flow - High (345.6” H2O)**
Located on CP004.