Before 1945 they were heavy weight __-__lbs per sq/ft
1945-1968 medium weight __-__lbs per sq/ft
After 1968 light weight __-__ per sq/ft

A

Before 1945 = 20-23lbs
1945-1968= 10-20lbs
After 1968 = 8-10lbs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Hi-rise
Fire damper used to restrict passage of (heat or fire).

To place in non-circulating mode do you open or close: mixing dampers, exhaust dampers, outside air dampers? In what order?

A

Fire damper used to restrict passage of heat

Non circulating mode:
Open Outside air dampers
Close Mixing dampers
Open Exhaust dampers

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Hi-rise
Is the fire tower the preferred evacuation stair or attack stair?

Fire pump bypass valve should be in the closed or open position?

How do you operate the fire pumps?

A

Fire tower is preferred evacuation stair

Fire pump bypass in closed position

Operate fire pumps (KC start the Lever):
Knife switch closed
Circuit breaker closed
Push start button
move Lever to desired position
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Hi-rise
What are the 4 building systems FD must gain control of?

Smoke or fire showing from exterior or serious fire has been verified is what (10-75 or 2nd alarm)

A

4 building systems (CHEF) communications, HVAC, elevators, Fire pumps

2nd alarm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Hi-rise
What ladder search the upper floors and attack stair?

What tools does the Cfr engine bring?

Vent is controlled by who?

A

4th ladder does upper floors and attack stair

CFR engine brings Cfr equipment and entry tools

All vent controlled by IC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Hi rise
What floors are the fire sector?

1st officer on scene assumes control of the ICP, if he leave lobby before chief arrival designate a member to man the lobby, preferably who?

A

Fire sector is fire floor and floor above

Preferably the 1st LCC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Hi rise
What channel does the SAE group operate on?

The forward staging area has how many spare cylinders? And how many engines and ladders?

A

SAE group on secondary tactical channel (3)

Forward staging area has 20 cylinders and 3 engine and 2 trucks in stand by

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Hi rise
What tools do ladders ordered to the forward staging area bring?

Should fixed stairwell pressurization systems be augmented by fans?

A

Ladders at forward staging area bring: scba for each member, 2 sets of irons, 6’ hooks, search and utility ropes, spare cylinder each

Do not augment fixed stairwell pressurization systems

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Hi rise
Stack effect
Most noticeable in buildings over __ft tall
Negative is (up/down) movement of air and is most likely when outside air temp is above __degrees

A

Most noticeable in building over 60ft tall

Negative is down, over 90 degrees outside

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Hi rise

Where is the SAE group located?

A

Floor which is not serviced by the same bank of elevators as fire floor (if possible). And at least 5 floors above fire floor

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Hi rise
Group supervisor can supervise __-__ units

Where is the forward staging area?

Where is the forward triage area?

A

Group supervisor can supervise 3-7 units

Forward staging area is 2 floors below fire
Forward triage area is floor below forward staging area

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Hi rise
Manual pull stations no more then __ft apart

Will a detector activation at an elevator landing recall the elevators? What about a water flow alarm? Activation of device in HVAC system?

A

Manual pull station no more then 200ft apart

Detector activation at elevator landing and water flow alarms will recall the elevators

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Hi rise
Who determines attack stair?

Should each ladder take their own elevator?

A

1st ladder determines attack stair

2nd and 3rd ladder if possible should take the 1st ladders elevator

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Hi rise

What stair does the 3rd ladder take to get to the floor above?

Who determines the evacuation stair?

Who removes all occupant from the attack stair and for how many floors above the fire?

A

3rd ladder uses a stair other then attack stair to get to floor above

3rd ladder determines evacuation stair

3rd ladder will remove all persons from attack stair for a reasonable distance above fire floor

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Hi rise

If the 3rd ladder encounters difficulty clearing the attack stair who do they advise to withhold the attack?

A

If 3rd ladder encounters difficulty clearing attack stair notify the 1st ladder and fire sector supervisor to withhold the attack

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Hi rise
The 4th ladder, what do they bring with them besides normal tools?

Where do they go? They do a primary of the top __floors
Who orders vent?
What is a logical assignment after roof ops are complete?

A

4th Ladder brings an extra cylinder
They go to the roof, primary of top 5 floors, IC orders vent
Logical assignment after roof ops complete is upper floors of elevator bank serving fire floor

17
Q

Hi rise
TorF 1st engine remains at ICP until fire location verified by 1st ladder company

What info is obtained from the fire safety director?

A

TRUE

Info obtained from fire safety director (LESA)
Location of fire
Evacuation procedures that have been implemented
Status of elevators
Access stairs serving the fire floor

18
Q

Hi rise

TorF 2nd engine officer remains at standpipe outlet until line is operating at correct nozzle pressure

A

True