Chapter 21 - TIC Flashcards
what is the camera we use?
MSA 5200 TIC thermal imaging camera
infrared emitters x 3
passive - absorb and disipate - chair
active - emit ir energy in low to medium strength - me
direct - constant high strength ir emitter - hot water tank
modes of operations
normal mode
high sensitivity low temp (0-320degrees f)
275 - yellow
297 - red
the gauge on right spans temps 0-302
ff mode low sensitivity and high temp illuminated L in lower left corner -842 - yellow then orange - 914 - red - 1040 degrees f
camera freezes or shutters every 45 seconds for recalibration. green square top left
toc 3 keys to effective ops
orientations
interpretation
communication
what are the scanning priorities?
Scan cieling - temp variation and elevation
scan the centre of the room - looking for exits and openings
scan the floor - looking for hazards and patients
scan behind as u progress to ensure nothing is missed