B787 MEMORY ITEMS Flashcards
1
Q
ABORTED ENGINE START L, R
A
- FUEL CONTROL switch (affected side) ….. CUTOFF
2
Q
AIRSPEED UNRELIABLE
A
- Autopilot disconnect switch - Push
- A/T ARM switches (both) - OFF
- F/D switches (both) - OFF
- Set the following gear up pitch attitude and thrust:
Flaps extended - 10* and 85% N1
Flaps up - 4* and 70% N1
3
Q
CABIN ALTITUDE
A
- Don the oxygen masks
- Establish crew communications
- Check the cabin altitude and rate
- IF the cabin altitude is uncontrollable:
PASS OXYGEN switch - Push to ON and hold for 1 second Emergency descent - Initiate
Thrust levers (both) - Idle
Speedbrake - UP
IF the structure is normal:
Target Speed - VMO/MMO
IF the structure is damaged:
Target speed - At or below current IAS
Avoid high manoeuvring loads
Transponder - 7700
Descend to the lowest safe altitude or 10,000 feet, which ever is the higher
4
Q
DUAL ENG FAIL/STALL [RR]
A
- FUEL CONTROL switches (both) - CUTOFF, then RUN
- RAM AIR TURBINE switch - Push and hold for 1 second
5
Q
ENG AUTOSTART L, R
A
- FUEL CONTROL switch (affected side) - Confirm - CUTOFF
6
Q
ENGINE LIMIT EXCEED L, R
A
- A/T ARM switch (affected side) - confirm - OFF
- Thrust lever (affected side) - confirm - Retard until ENG LIMIT EXCEED message blanks or the thrust lever is at idle
7
Q
ENGINE SURGE L, R
A
- A/T ARM switch (affected side) - confirm - OFF
- Thrust Lever (affected side) - confirm - Retard until ENG SURGE message blanks or the thrust lever is at idle
8
Q
ENG SVR DAMAGE/SEP L, R
A
- A/T ARM switch (affected side) - confirm - OFF
- Thrust lever (affected side) - confirm - Idle
- FUEL CONTROL switch (affected side) - confirm - CUTOFF
- Engine fire switch (affected side) - confirm - Pull
9
Q
FIRE ENGINE L, R
A
- A/T ARM switch (affected side) - confirm - OFF
- Thrust lever (affected side) - confirm - Idle
- FUEL CONTROL switch (affected side) - confirm - CUTOFF
- Engine fire switch (affected side) - confirm - Pull
- IF the FIRE ENG message stays shown:
Engine fire switch (affected side) - Rotate to the stop and hold for 1 second
10
Q
STABILIZER
A
- STAB cutout switches (both) - CUTOUT
- Do not exceed the current airspeed
11
Q
FD Door Auto Unlock
A
- FD DOOR ACCESS selector - Rotate to deny & hold for 1 second