APU *** Flashcards
* 14 Questions *
What are the start sources for the APU, and which one do we normally use?
- TR (Transformer-Rectifier Unit), when Utility Bus 4 is powered.
- APU Battery, when Utility Bus 4 is unpowered.
Normally use Battery
Can the APU be operated in flight?
• Yes, when left running for takeoff it can be operated in flight up to 20,000 feet
Is electrical power available from the APU in flight? How about APU bleed air in flight?
- No, APU electrical power is not available in flight
* Yes, APU bleed air is available in flight for one pack up to 15,000 feet
What APU components are powered by main hot battery and the main battery bus
- APU Fire Ext (HOT)
- APU Fuel Valve SOV (HOT)
- APU Secondary Controller (MAIN)
(Fire - Fuel - Controller)
What APU components are powered by APU battery?
- Inlet Door (Hot)
- APU Primary Controller (Hot)
- DC Fuel Pump (Main)
- APU Fire Detection System (Main)
(Fire - Fuel - Controller + Door)
What powers the APU starter during a battery start sequence?
- The APU battery
* (All other APU components are powered by the main battery while the APU starter is engaged)
APU Start Cycles
Between start through battery (atlas )
1 and 2 :—-> 1 minute
2 and 3 :—-> 1 minute
3 and 4 :—-> 75 minute
What happens if TR overheats with start source in TR?
Start power is transferred to the battery.
Further attempts with overheated TR inhibited.
How does a TR failure affect APU starting?
• Automatic switching to the APU battery is not provided
• Moving the start switch to BATTERY removes the TR from the starting
circuit and allows APU starting on battery power.
When does the EICAS memo message APU RUNNING display?
• When the APU selector is ON and APU N1 RPM exceeds 95% N1.
Describe the APU shutdown sequence.
- Rotating the APU selector to OFF begins the shutdown cycle
- APU bleed air valve closes
- APU continues running unloaded for a 60-second cooldown period.
- When the cooldown period finishes, the APU shuts down.
What would happen if the battery switch is positioned OFF prior to completion of the APU shutdown cooldown period?
• It will shut down immediately as the DC pump is de-energized.
Remember, it’s on the APU MAIN BUS not APU HOT BUS.
How long should you wait before turning the battery switch OFF after the APU selector is rotated to OFF, and why?
- 2 minutes
* Allows a complete shutdown sequence, with fire detection capability.
What would cause the APU to shut down immediately?
- A limit is exceeded
- A fire is detected
- Battery switch turned off during APU shutdown sequence.
APU Selector: OFF
- APU BLEED CLOSED
- Initiates SHUTDOWN
- resets auto-shutdown fault logic except w/shutdown due to APU bleed air leak