APU *** Flashcards

* 14 Questions *

1
Q

What are the start sources for the APU, and which one do we normally use?

A
  • TR (Transformer-Rectifier Unit), when Utility Bus 4 is powered.
  • APU Battery, when Utility Bus 4 is unpowered.

Normally use Battery

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Can the APU be operated in flight?

A

• Yes, when left running for takeoff it can be operated in flight up to 20,000 feet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Is electrical power available from the APU in flight? How about APU bleed air in flight?

A
  • No, APU electrical power is not available in flight

* Yes, APU bleed air is available in flight for one pack up to 15,000 feet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What APU components are powered by main hot battery and the main battery bus

A
  • APU Fire Ext (HOT)
  • APU Fuel Valve SOV (HOT)
  • APU Secondary Controller (MAIN)

(Fire - Fuel - Controller)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What APU components are powered by APU battery?

A
  • Inlet Door (Hot)
  • APU Primary Controller (Hot)
  • DC Fuel Pump (Main)
  • APU Fire Detection System (Main)

(Fire - Fuel - Controller + Door)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What powers the APU starter during a battery start sequence?

A
  • The APU battery

* (All other APU components are powered by the main battery while the APU starter is engaged)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

APU Start Cycles

A

Between start through battery (atlas )

1 and 2 :—-> 1 minute
2 and 3 :—-> 1 minute
3 and 4 :—-> 75 minute

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What happens if TR overheats with start source in TR?

A

Start power is transferred to the battery.

Further attempts with overheated TR inhibited.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

How does a TR failure affect APU starting?

A

• Automatic switching to the APU battery is not provided
• Moving the start switch to BATTERY removes the TR from the starting
circuit and allows APU starting on battery power.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

When does the EICAS memo message APU RUNNING display?

A

• When the APU selector is ON and APU N1 RPM exceeds 95% N1.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Describe the APU shutdown sequence.

A
  • Rotating the APU selector to OFF begins the shutdown cycle
  • APU bleed air valve closes
  • APU continues running unloaded for a 60-second cooldown period.
  • When the cooldown period finishes, the APU shuts down.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What would happen if the battery switch is positioned OFF prior to completion of the APU shutdown cooldown period?

A

• It will shut down immediately as the DC pump is de-energized.
Remember, it’s on the APU MAIN BUS not APU HOT BUS.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

How long should you wait before turning the battery switch OFF after the APU selector is rotated to OFF, and why?

A
  • 2 minutes

* Allows a complete shutdown sequence, with fire detection capability.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What would cause the APU to shut down immediately?

A
  • A limit is exceeded
  • A fire is detected
  • Battery switch turned off during APU shutdown sequence.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

APU Selector: OFF

A
  • APU BLEED CLOSED
  • Initiates SHUTDOWN
  • resets auto-shutdown fault logic except w/shutdown due to APU bleed air leak
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

APU Selector: ON

A
  • Opens APU fuel valve and inlet door
  • Arms APU bleed air isolation valve
  • Activates DC or two AC fuel pumps
17
Q

APU Cool down period?

A

Starts when switch placed in OFF and lasts for one minute (60 seconds)
Wait 2 minutes after shutdown before turning off battery switch. This ensures fire detection capability.

18
Q

APU auto shutdown items (3)?

A
  • Limit Exceedence
  • Fire
  • Battery Switch Off
19
Q

What fuel pumps provide pressure for APU?

A

Main Tank 2 AFT AC PUMP
- otherwise -
Main Tank 2 DC

*Main Tank 3 AFT AC PUMP prevents xfer and is a backup.

20
Q

APU generators and load?

A
  • 2 gens
  • Capable of supplying entire load of A/C on ground
  • Not avail in flight
21
Q

When is APU cool down cycle complete?

A

When fuel valve closes and APU decelerates.

22
Q

Is APU GEN power available during cool down cycle?

A

NO