SCBA And Respiratory Protection Program Flashcards

1
Q

SCBA And Respiratory Protection Program - SCBA’s shall be worn for the following conditions:

A
  • IDLH
  • Unknown atmosphere
  • Atmosphere known to be hazardous
  • Atmosphere rapidly becomes hazardous (e.g. Driver operator when the wind changes)
  • below ground or in confined space
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

SCBA And Respiratory Protection Program - define the following:

  • speaker module
  • control module
  • transfill
  • UAC
  • HUD
  • Retention band
  • Serviceable tunnel
A
  • provides voice amp
  • user feedback on air supply and pack functions
  • EBSS system allowing exchange of air between FF’s
  • Universal air connection
  • Heads up display
  • holds the air cylinder to the harness
  • removeable fabric protection component that can be decontaminated
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

SCBA And Respiratory Protection Program - Cylinders full @ _ psi

  • Recharge after _ days past last fill date
  • Filling locations include?
A
  • 4000psi or greater
  • 90 days
  • 101, 116, 118, GWMC
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

SCBA And Respiratory Protection Program - Visual and functional tests shall be done when?

A
  • Beginning of each shift
  • receipt of a replacement SCBA
  • after every use
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

SCBA And Respiratory Protection Program - Low air levels on HUD alarm at?

A

1575 psi (33%)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

SCBA And Respiratory Protection Program - once officer observes a member of their crews buddy lights have turned yellow, indicating 50%, the officer shall:

A
  • consider completing the assigned task and having the crew exit the IDLH atmosphere
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

SCBA And Respiratory Protection Program - 3 SCBA emergency operations:

A
  1. Low air - notify officer and exit as a crew
  2. Pressure reducer primary stage failure - notify officer and exit as a crew
  3. Failure open - blue flashing light in HUD and control module, open bypass valve fully and control air supply using the cylinder hand wheel. Exit as a crew
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

SCBA And Respiratory Protection Program - Officer or FF should consider calling a MAYDAY and later require an investigation, remove pack from service for inspection and testing when:

A
  • Pressure reduce primary stage failure

- Failure open

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

SCBA And Respiratory Protection Program - Fit tests shall be carried out for the following occasions:

A
  • prior to initial use (new hires)
  • Annually
  • Change in respiratory face piece (model/size)
  • Change in the users physical condition
  • be clean shaven, not smoked within 30 min, records will be maintained
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

SCBA And Respiratory Protection Program - MFES SCBA users shall train in an IDLH environment at least _?

A

Annually

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

SCBA And Respiratory Protection Program - What test is it called when you “shut cylinder off for 10 seconds, and if there’s a loss of more than 100 PSI over 10 seconds, that’s unacceptable and the unit should be taken out of service?”

A

Drop leak test

How well did you know this?
1
Not at all
2
3
4
5
Perfectly