SCBA And Respiratory Protection Program Flashcards
SCBA And Respiratory Protection Program - SCBA’s shall be worn for the following conditions:
- IDLH
- Unknown atmosphere
- Atmosphere known to be hazardous
- Atmosphere rapidly becomes hazardous (e.g. Driver operator when the wind changes)
- below ground or in confined space
SCBA And Respiratory Protection Program - define the following:
- speaker module
- control module
- transfill
- UAC
- HUD
- Retention band
- Serviceable tunnel
- provides voice amp
- user feedback on air supply and pack functions
- EBSS system allowing exchange of air between FF’s
- Universal air connection
- Heads up display
- holds the air cylinder to the harness
- removeable fabric protection component that can be decontaminated
SCBA And Respiratory Protection Program - Cylinders full @ _ psi
- Recharge after _ days past last fill date
- Filling locations include?
- 4000psi or greater
- 90 days
- 101, 116, 118, GWMC
SCBA And Respiratory Protection Program - Visual and functional tests shall be done when?
- Beginning of each shift
- receipt of a replacement SCBA
- after every use
SCBA And Respiratory Protection Program - Low air levels on HUD alarm at?
1575 psi (33%)
SCBA And Respiratory Protection Program - once officer observes a member of their crews buddy lights have turned yellow, indicating 50%, the officer shall:
- consider completing the assigned task and having the crew exit the IDLH atmosphere
SCBA And Respiratory Protection Program - 3 SCBA emergency operations:
- Low air - notify officer and exit as a crew
- Pressure reducer primary stage failure - notify officer and exit as a crew
- Failure open - blue flashing light in HUD and control module, open bypass valve fully and control air supply using the cylinder hand wheel. Exit as a crew
SCBA And Respiratory Protection Program - Officer or FF should consider calling a MAYDAY and later require an investigation, remove pack from service for inspection and testing when:
- Pressure reduce primary stage failure
- Failure open
SCBA And Respiratory Protection Program - Fit tests shall be carried out for the following occasions:
- prior to initial use (new hires)
- Annually
- Change in respiratory face piece (model/size)
- Change in the users physical condition
- be clean shaven, not smoked within 30 min, records will be maintained
SCBA And Respiratory Protection Program - MFES SCBA users shall train in an IDLH environment at least _?
Annually
SCBA And Respiratory Protection Program - What test is it called when you “shut cylinder off for 10 seconds, and if there’s a loss of more than 100 PSI over 10 seconds, that’s unacceptable and the unit should be taken out of service?”
Drop leak test