What are the various functions of the RH system?
Remove heat from the core during the second phase of plant cooldown
Serve as the low pressure high volume segment of ECCS
Transfers refueling water between the RWST and refueling cavity
What is the design basis of the RH system?
Placed in operation 4 hours after shutdown <350F and <360psig
Reduced RCS temp from 350F to 140F within 36 hours (2 trains)
Reduce RCS temp from 350F to 200F within 44 hours (1 train)
Uses 5000 gpm CC flow at 105F max temp
ECCS operation available for 1 year following LOCA with single failure
What is the flowpath of the RH system during ECCS injection during modes 1-3?
RWST –> SI8812 –> RH PP –> RH HX –> RH606 –> RH8809 –> A & D Cold Legs
What is the flowpath during normal alignment in Mode 4?
One train in ECCS injection and one train on SDC.
What is the flow path of Mode 6 alignment during cavity fill?
One train on SDC: Hot leg –> Cold Legs & CVCS
One train on cavity fill: RWST –> Hot Legs A&C
What is the flow path alignment during Mode 6 cavity drain?
One train on SDC: A Hot Leg –> Cold Legs A&D & CVCS
One train on cavity drain: Hot Leg C –> RWST
Why is a portion of RH flow diverted to the CVCS during shutdown cooling operations?
Permits clean up of RCS during RH operation
Pressure control of RCS with pressurizer water solid
Used for letdown of RCS when pressure is too low
What is the RH pump design flow and pressure?
3000 GPM @ 165 psid
What is the RH pump runout flow and pressure?
5000 GPM @ 125 psid
What is the shutoff head of the RH pump?
200 psid
When do the RH system relief valves lift?
Suction 450 psig
Discharge 600 psig
When is the RH system placed into operation?
<350F and <360 psig after 4 hours of shutdown
How is RCS temp controlled while utilizing RH on SDC?
Bypass valve automatically controls to maintain 3300 gpm
HX outlet valve 606 & 607 manually adjusted to maintain cooldown rate
What setpoints and operations do the mini flow recirc valves operate on?
A flow element on the discharge line senses when to operate valve; open <750 gpm, closes >1400 gpm
What controls for the Rh system are available on the RSDP?
None, temperature instrumentation is locally mounted in the RH HX rooms