impression faults Flashcards

1
Q

What are 5 reasons for the incomplete reproduction of preparation margins?

A
  1. insufficient retraction
  2. blood and saliva contamination
  3. impaired flow ability due to exceeding working time
  4. inadequate coverage of the area with light body
  5. impression material has a low tear resistance
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

6 causes of voids on the margin:

A
  1. blood and saliva contamination
  2. improper syringe technique
  3. working time exceeded (impaired flow ability)
  4. air bubbles in syringes
  5. tray not seated properly
  6. stored at a higher temperature
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

6 causes of voids on the margin:

A
  1. blood and saliva contamination
  2. improper syringe technique
  3. working time exceeded (impaired flow ability)
  4. air bubbles in syringes
  5. tray not seated properly
  6. stored at a higher temperature
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Causes of tearing at the margin:

A
  1. insufficient retraction
  2. inadequately mixed materials
  3. premature removal of the impression
  4. imp material has low tear resistance
  5. expired impression material
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Causes of distortions in the final impression:

A
  1. working time exceeded
  2. lack of support / stabilisation of the tray by the operator
  3. distortions during impression removal
  4. inappropriate combination of the tray and impression material
How well did you know this?
1
Not at all
2
3
4
5
Perfectly