Fire Protection Flashcards

1
Q

What is the indication for an APU fire?

A

1) Continuous Repetitive Chime (CRC sounds)
2) Red MASTER WARN Lights Flash
3) Red guarded APU FIRE light illuminates on the overhead FIRE panel
4) APU page appears on the SD

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

How many Halon Fire bottles are available for each engine, the APU and cargo compartments

A

1) Each engine has 2 bottles
2) APU has one bottle
3) Fwd and Aft cargo compartments share 1 bottle

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

How and when will the APU automatically shut down (automatic fire protection function)

A

the master computer will automatically perform and APU EMER SHUTDOWN and discharge the APU fire extinguisher ONLY on the ground

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What type of smoke detector system is available in the avionics compartment? Is heat sensing available?

A

Smoke detectors sense particulates. Heat sensing is not available

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Where is the Aft Cargo compartment temperature displayed and monitored

A

Either the ECAM COND page or ECAM CRUISE page

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What are the exterior aircraft indications of an APU fire

A

1) External Warning Horn Sounds
2) Red APU fire light illuminates on External Power Panel

How well did you know this?
1
Not at all
2
3
4
5
Perfectly