ELECTRICAL SYSTEM Flashcards
WHAT ARE THE ELECTRICAL POINTS OF GENERATION?
2 ENG GENS
1 EMER GEN, RAT VIA BLUE HYD PUMP
1 APU
HOW MUCH POWER CAN EACH GENERATOR SUPPLY?
GEN 1/2, APU 90KVA 115/200 V 400 Hz power
EMER GEN 5KVA 115/200 V 400Hz power
FCOM-DSC-24-10-20
WHAT DOES IDG STAND FOR?
INTEGRATED DRIVE GENERATOR
AT WHAT TEMP WILL THE IDG FAULT LIGHT COMES ON?
180C
There is a automatic thermal disconnection at 200C
WHAT ARE THE NORMAL GEN OPERATING RANGES?
110-120V
390-410Hz
below 110%
FCOM overhead panel
WHAT DOES GALLEY SHED MEMO INDICATE?
GALLEY pb-sw is OFF
only 1 GEN operating
On GND A/C being supplied by 1 GEN
FCOM DSC OVERHEAD PANEL
HOW MANY APU STARTS ARE ALLOWED?
3 consecutive starts then a 60min wait for a new start
FCOM LIM APU
WHAT DOES PRESSING THE “MAN ON” PB ON THE “EMER ELEC PWR” PANEL DO?
Pressing this will manually extend the RAT. Emergency generator coupling occurs 3s after the RAT supplies the emergency generator.
FCOM DSC-24-20