ELECTRIC SYS Flashcards
BATTERY LOCATION
NO 1 END ALL CARS
ALSO FUSES
BATTERY PURPOSE
INITIAL START, TO CLOSE RELAYS, CONTACTORS
PROVIDE EMERG LTS
BACKUP SYS IF AOD STOPS OR FAILS
BATTERY PROTECTION
BATTERY FUSES
BATTERY SAFETY
PANTOGRAPHS LOWERED
REVERSER INTO ISOLATION
TANGARA BATTERIES
LIGHTING AND CONTROL
LIGHTING BATTERIES
CONTROLS ALL LIGHTS
LIGHTING BATTERIES LOCATION
DT
NO 1 END
CONTROL BATTERIES
CONTROL CIRCUIT AND AUX RELAY
CONTROL BATTERIES
LOCATION
MOTOR CAR
NO 1 END
CONTROL JUMPER CARRIES
120 VDC
5 PIN
240/415
DOESNT CONNECT BETWEEN 4 CAR SETS
FROM BATT POSITIVE
TO INTERLOCK RELAY
TRAIN CONTROL MCB
TRAIN CONTROL CIRCUIT
BTITCM
FROM Batt
BATTERIES
TCMCB
IR
CG
TI
MC
CONTROL POSITIVE CIRCUIT
BATTERY
TCMCB
IR
CONTROL POSITIVE MCB
V IGO
I INTERCOM COMMS
B ELL
EP
BATTERY POSITIVE
INDICATION
CAB LT OR LED IN SPEEDOMETER
TRAIN CONTROL CIRCUIT BREAKER
INDICATION
CHECK CIRCUIT BREAKER UP POSITION
INTERLOCK RELAY
REVERSER OUT OF ISOLATION
CONTROL GOVERNOR
CLICKS CLOSES AT 350 KPA
BRAKE PIPE AIR WHEN CUTTING IN
TRACTION INTERLOCKING
OBSERVE TI LGT NOT ILLUMINATED. PRESS TI TEST BUTTON TO CHECK LT WORKS
MASTER CONTROLLER
RELEASE DEADMAN TO CHECK SAI COCK IS OPEN MAKE SURE BP AIR IS EXHAUSTING UNDER DRIVER
JUMPER CABLES
TRAIN CONTROL CABLES
BELL WITH GUARD
LOWER PANTOGRAPHS AND CHECK ALL LOWERED
RAISE PANTOGRAPHS AND CHECK ALL RAISED
MOTOR CUT OUT SW
CHECK HANDLE IN ROOF AND CHECK ON TMS SCREEN
TRACTION MOTOR LINE SWITCHES
CHK CRM AND CR1 ISOLATING COCKS ARE OPEN
HT1
HT2
HT3 ON T SET
RELAY
FUNCTION
AN ELECTRICAL DEVICE THAT INCORPORATES A SOLENOID CONTROLLED SW TO UTILISE CURRENT IN ONE CIRCUIT TO TURN ON AND OFF THE CURRENT IN ANOTHER CIRCUIT
RELAY SYS IN TRAIN INCLUDE:
AUX RELAY OVERLOAD RELAY OVERCURRENT RELAY OVERVOLTAGE RELAY INTERLOCK RELAY LINE SWITCHING PROTECTION RELAYS
OVERLOAD RELAY
TRACTION MOTOR
OVERCURRENT RELAY
OVERVOLTAGE RELAY
MA
INTERLOCK RELAY
REVERSER OUT OF ISOL
FIL
FAULT INDICATOR LT
TRAIN LINED
AFIL
AUX FAULT IND LT
CAR CONCERNED
2 CARS IF MA
1 CAR IF BATT CHARGER AS ONE EACH CAR
PFIL
POWER FAULT IND LT
CAR CONCERNED 2 CAR BLOCK
LVIL
LINE VOLTAGE IND LT
CAR CONCERNED
2 CAR BLOCK
AUX RELAY TO SET PRESS
PAN UP BUTTON
BATTERY CONTACTORS TO SET PRESS
PAN UP BUTTON
OVERLOAD RELAY TO SET PRESS
RESET BUTTON
K SET
PROTECTS TRACTION MOTORS SO DONT BE APPLYING POWER
HIGH SPEED BREAKER
TO SET PRESS
RESET BUTTON
C AND T SET
MC OFF AND DOORS CLOSED
PRESS 5 SECS AND WAIT 15 SECS
OVERCURRENT RELAY
TO SET PRESS
LGTS ON BUTTON
K C SET
PROTECTS MA
OVERVOLTAGE RELAY
TO SET PRESS
LGTS ON BUTTON
K C SET
PROTECTS MA
LINE SW PROTECTION RELAY
TO SET PRESS
MC OFF
RE APPLY POWER T SET
INTERLOCK RELAY
TO SET PRESS
REVERSER OUT OF ISOL
MOTIVE POWER RELAY
TO SET PRESS
PAN UP BUTTON T SET
FIL FUNCTION
INDICATE WHETHER TRAIN SYSTEMS ARE OPERATING NORMALLY OR IN FAULT MODE
CB AND FILS LOCATED
NO 2 END
FIL LT INDICATES
TRAIN LINE FAULT