ELECTRIC SYS Flashcards
BATTERY LOCATION
NO 1 END ALL CARS
ALSO FUSES
BATTERY PURPOSE
INITIAL START, TO CLOSE RELAYS, CONTACTORS
PROVIDE EMERG LTS
BACKUP SYS IF AOD STOPS OR FAILS
BATTERY PROTECTION
BATTERY FUSES
BATTERY SAFETY
PANTOGRAPHS LOWERED
REVERSER INTO ISOLATION
TANGARA BATTERIES
LIGHTING AND CONTROL
LIGHTING BATTERIES
CONTROLS ALL LIGHTS
LIGHTING BATTERIES LOCATION
DT
NO 1 END
CONTROL BATTERIES
CONTROL CIRCUIT AND AUX RELAY
CONTROL BATTERIES
LOCATION
MOTOR CAR
NO 1 END
CONTROL JUMPER CARRIES
120 VDC
5 PIN
240/415
DOESNT CONNECT BETWEEN 4 CAR SETS
FROM BATT POSITIVE
TO INTERLOCK RELAY
TRAIN CONTROL MCB
TRAIN CONTROL CIRCUIT
BTITCM
FROM Batt
BATTERIES
TCMCB
IR
CG
TI
MC
CONTROL POSITIVE CIRCUIT
BATTERY
TCMCB
IR
CONTROL POSITIVE MCB
V IGO
I INTERCOM COMMS
B ELL
EP
BATTERY POSITIVE
INDICATION
CAB LT OR LED IN SPEEDOMETER
TRAIN CONTROL CIRCUIT BREAKER
INDICATION
CHECK CIRCUIT BREAKER UP POSITION
INTERLOCK RELAY
REVERSER OUT OF ISOLATION
CONTROL GOVERNOR
CLICKS CLOSES AT 350 KPA
BRAKE PIPE AIR WHEN CUTTING IN
TRACTION INTERLOCKING
OBSERVE TI LGT NOT ILLUMINATED. PRESS TI TEST BUTTON TO CHECK LT WORKS
MASTER CONTROLLER
RELEASE DEADMAN TO CHECK SAI COCK IS OPEN MAKE SURE BP AIR IS EXHAUSTING UNDER DRIVER
JUMPER CABLES
TRAIN CONTROL CABLES
BELL WITH GUARD
LOWER PANTOGRAPHS AND CHECK ALL LOWERED
RAISE PANTOGRAPHS AND CHECK ALL RAISED
MOTOR CUT OUT SW
CHECK HANDLE IN ROOF AND CHECK ON TMS SCREEN
TRACTION MOTOR LINE SWITCHES
CHK CRM AND CR1 ISOLATING COCKS ARE OPEN
HT1
HT2
HT3 ON T SET
RELAY
FUNCTION
AN ELECTRICAL DEVICE THAT INCORPORATES A SOLENOID CONTROLLED SW TO UTILISE CURRENT IN ONE CIRCUIT TO TURN ON AND OFF THE CURRENT IN ANOTHER CIRCUIT
RELAY SYS IN TRAIN INCLUDE:
AUX RELAY OVERLOAD RELAY OVERCURRENT RELAY OVERVOLTAGE RELAY INTERLOCK RELAY LINE SWITCHING PROTECTION RELAYS
OVERLOAD RELAY
TRACTION MOTOR
OVERCURRENT RELAY
OVERVOLTAGE RELAY
MA
INTERLOCK RELAY
REVERSER OUT OF ISOL
FIL
FAULT INDICATOR LT
TRAIN LINED
AFIL
AUX FAULT IND LT
CAR CONCERNED
2 CARS IF MA
1 CAR IF BATT CHARGER AS ONE EACH CAR
PFIL
POWER FAULT IND LT
CAR CONCERNED 2 CAR BLOCK
LVIL
LINE VOLTAGE IND LT
CAR CONCERNED
2 CAR BLOCK
AUX RELAY TO SET PRESS
PAN UP BUTTON
BATTERY CONTACTORS TO SET PRESS
PAN UP BUTTON
OVERLOAD RELAY TO SET PRESS
RESET BUTTON
K SET
PROTECTS TRACTION MOTORS SO DONT BE APPLYING POWER
HIGH SPEED BREAKER
TO SET PRESS
RESET BUTTON
C AND T SET
MC OFF AND DOORS CLOSED
PRESS 5 SECS AND WAIT 15 SECS
OVERCURRENT RELAY
TO SET PRESS
LGTS ON BUTTON
K C SET
PROTECTS MA
OVERVOLTAGE RELAY
TO SET PRESS
LGTS ON BUTTON
K C SET
PROTECTS MA
LINE SW PROTECTION RELAY
TO SET PRESS
MC OFF
RE APPLY POWER T SET
INTERLOCK RELAY
TO SET PRESS
REVERSER OUT OF ISOL
MOTIVE POWER RELAY
TO SET PRESS
PAN UP BUTTON T SET
FIL FUNCTION
INDICATE WHETHER TRAIN SYSTEMS ARE OPERATING NORMALLY OR IN FAULT MODE
CB AND FILS LOCATED
NO 2 END
FIL LT INDICATES
TRAIN LINE FAULT
WHEEL SLIP WSIL LT INDICATES
TRAIN LINE AND SPRING PB APPLIED
TRACTION INTERLOCK LT
TRAIN LINE NO TRACTION POWER AVAIL
PFIL LT SHOWS
POWER FAULT CAR CONCERNED
LVIL SHOWS
LINE VOLTAGE CAR CONCERNED
FOR LOSS OF OVERHEAD
AFIL SHOWS
AUX FAULT CAR CONCERNED
RBIL LT SHOWS
REGEN ELECTRIC BRAKE C SET
ALL ELECTRIC CONTROLS
NO 2 END
PANTOGRAPH
BATTERY
BATTERY CHARGER
NO 1 END
RESET PB
OVERLOAD RELAY
HSB
LIGHTS ON PB
OVERCURRENT
OVERVOLTAGE
K AND C ONLY
PAN UP PB
SETS AUX RELAY
PAN DOWN PB
TRIPS AUX RELAY
BELL PB
BELL INTERLOCK RELAY ENERGISED
TEST PB
TEST FIL WORK
VIGILANCE BUTTON PB
ACKNOWLEDGE VIGILANCE
EMPB PB
BYPASS CONTROL GOVERNOR
TI TEST BUTTON PB
TEST TI
TI FUNCTION TEST
TI OVERRIDE BUTTON
TEMPORARY OVERRIDE TI
SALOON LTS PB
EMERG LTS
AND
RESET BATT CHARGER FAULT
T SET
PARKING BRAKE PB
APPLY AND RELEASE SPB ALL CARS
T SET
QUICK TMS RESET PB
QUICK RESET OF TMS
TMS SHUTDOWN
PERMISSION REQD FOR COMPLETE REBOOT
EXCEPT FOR PREP NEED TO TALK TO MECH CONTROL
UNCOUPLE BUTTON PB
ZERO BP
AND
REV OUT OF ISOL
T SET
MCBs
FUNCTION
SAFETY MEASURE TO STOP THE FLOW OF ELECTRIC CURRENT IF REQUIRED
SOME OF THE KEY MCBs ARE
TRAIN CONTROL CONTROL POSITIVE VIGILANCE CONTROL TMS CONTROL DOIL COMP GOV COMP SYNC
JUMPER COUPLINGS FUNCTION
ENABLE VARIOUS FUNCTIONS TO TAKE PLACE BY ALLOWING THE FLOW OF LOW TENSION CURRENT TO OCCUR BETWEEN CARS
CONTROL JUMPER VOLTAGE
120V
5 PIN JUMPER V
240 VAC
415 VAC
5 PIN JUMPER PROVIDES
415 - AIR COND K AND C SET
CHOPPER UNIT C SET
NOT BETWEEN 4TH AND 5TH CAR
ELECTRICAL HEADS V
120 V
SWITCHES
FUNCTION
DEVICE FOR OPENING AND CLOSING A CIRCUIT
OPENING A CIRCUIT MEANS
TO TURN OFF
CLOSING A CIRCUIT MEANS
TO TURN ON
MCOS
MOTOR CUT OUT SW
ALL SETS
ISOLATES TRACTION MOTORS
K C SETS
SIS
SUPPLY INDICATOR SW
EXTINGUISHES FAULT LT WHEN BATTERY CHARGER FAULT CANNOT BE RECTIFIED
K C SET
SSS
SUPPLY SELECTOR SW
TURNS ON AND OFF MA TO GET EMERG FEED FROM NEXT WORKING MA AOD
BCOS
T SET
BATTERY CHANGEOVER SW
DRAWS A BATTERY FEED FROM THE LIGHTING BATTERIES FOR CONTROL CCT IF CONTROL BATTERIES ARE SET
TEST SW
T SET
USED BY MAIN STAFF TO TEST POWER SEQ
MUST BE KEPT IN NORMAL OTHERWISE THAT CAR WILL NOT POWER
TMS STANDS FOR
TRAIN MGMT SYS
TMS FUNCTION
INDICATE WHETHER TRAIN SYS ARE OPERATING NORMALLY OR IN FAULT MODE
TMS ROLES
MONITORS ABD RECORDS CONDITION OF ALL MAJOR EQUIP
ADVISES ABD RECORDS ABNORMAL OCCURRENCES
RECOMMENDS RECTIFICATION
CUTTING OUT SIV AND TRACTION MOTORS VIA DDU
TRACTION INTERLOCKING
TMS PROTECTION
TMS MCB
TMS RISKS
TRACTION INTERLOCKING NOT WORKING ON THAT CAR
NOTIFY GUARD TO BE EXTRA VIGILANT WITH DOORS
MASTER CONTROLLER
FUNCTION
USED TO CONTROL POWER TO THE TRACTION MOTORS WHICH IN TURN CONTROL ACCEL OF THE TRAIN
CAMSHAFT CARS
K SET
1 NOTCH NO LONGER THAN 5 SECS
CHOPPER CARS
C AND T SETS
TANGARA MASTER CONTROLLER
CAN NOTCH DOWN POWER
REVERSER FUNCTION
PROVIDES DIRECTIONAL AND ISOL CONTROL THROUGH A VOLT SUPPLY TO EQUIP
REVERSER OPERATION
HANDLE IS SEL ONLY
REVERSER SITS ON TOP OF THE MOTOR
REVERSER REQUIRES CONTROL RESERVOIR AIR TO CHANGE DIRECTION ON CAMSHAFT CARS
TRACTION MOTORS
FUNCTION
RECEIVE HIGH TENSION CURRENT FROM THE OVERHEAD SUPPLY AND CONVERT THE ELEC ENERGY INTO TRACTIVE FORCE TO DRIVE THE WHEELS
CAMSHAFT MOTORS?
K SETS
CHOPPER MOTORS?
C AND T SETS
K AND C SETS WHERE ARE MOTORS
1
4
5
8
T SETS
WHERE ARE MOTORS
2
3
6
7
AOD
FUNCTION
PROVIDES POWER FOR THE CONTROL/ LIGHTING CCTS, AIR COND AND BATT CHARGERS
AOD
K AND C SET
MA
AOD
T SET
SI
AOD LOCATION
K AND C SET
FLOOR NO 2 END TRAILING CAR
T SET
ROOF NO2 END DT
AOD REQUIRES
1500V
AIR CR1 CRM
AOD PROTECTION
AUX RELAY
OVERCURRENT RELAY
OVER VOLTAGE RELAY
HSB
AOD OUTPUT
415 VAC
240 VAC
120 VDC
WHAT CHARGES THE BATTERY
BATTERY CHARGER
WHAT RUNS ON 415 VAC
AIR COND
CHOPPER UNIT C SET ONLY
BATTERY CHARGING T SET
AIR COND LOCATION
ROOF DIRECTLY ABOVE VESTIBULE AREA
240 VAC POWERS
MAIN LGTS K AND C SETS FOG LGT T SET HEATERS DEMISTERS HEADLGTS
120V POWERS
FAULT LGTS MAIN LGTS T SET DOORS T SET EMERG FANS TRAIN CONTROL CURRENT BATTERY CHARGING K AND C SET CHOPPER UNIT T SET
SIS LOCATION
EVERY CAR
AS
BATT CHARGER EVERY CAR
SSS LOCATION
TRAILER CAR
AS MA IN TRAILER CAR