Chapter 3 stuff Flashcards

1
Q

What is the priority order for the use of PPV:

A

Pressurizing he attack stairwell Pressurizing the evacuation stairwell Venting the Public hallways for smoke and CO

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Timber is wood construction larger than

A

2x4 but not large enough to be considered heavy time or mill construction. Dunn Brkdwn pg 41

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Mill lofts construction feature, wooden columns are how large?

A

6 – 10 inches in diameter and topped with iron caps. Lofts 5.3.2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Square columns in lofts are used where?

A

On lower floors and are 20% stronger than round ones of equal dimension. Lofts 5.3.2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Some Mill “hybrid” buildings have what type of columns?

A

Protected cast-iron columns

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Timber Truss Roof can be built in what shapes?

A

Inclined Plan truss (Gable shape) Parallel Chord Truss (Flat) Bowstring Truss – most common

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

When is the command channel implemented?

A

10-60 10-66 10-76 3rd alarm or greater 10-77 and more than one sector is established. {On a regular 77, only one sector is established, the Fire Sector.} Complex Operations as per the IC Comm Man 11 7.3.2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

When are Command Channel training drills held?

A

May and November. At 2nd alarms, all large scale drills and discussed at Division Conferences.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Tactical Supervisors that operate on the Tactical Channel are: Comm. Man 11 7.3.5.B

A

Sector Supervisors and or Branch Director (DC) Fire Floor, Floor Above, Roof Sector, Exposure Sectors, Group Supervisors, Search and Rescue Group Supervisor, Collapse Group Supervisor Safety Officer, Resource Unit Leader

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Which Chiefs operate on the Command Channel?

A

Officers assigned to Planning Chief, Staging Area Manager, Air Recon

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

No member shall operate on other than the primary Tactical Channel with authorization of?

A

The IC or the Resource Unit Leader.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

When does the Hi Rise Unit respond?

A

Any second alarm in conjunction with a 10-77. 10-76 and greater Any underground subway incident that is a 7-5 or greater. Special called

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Who authorizes Agency data code 9111?

A

The Chief of Operations, Used for preparedness work, or emergency response. 4Q Update, AUC 159, Add 5, 1.11

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

When the Fire Saftey Director is not present, and there is less than 100 above/below and less than 500 people in entire bldg, who is that person?

A

Building Evacuation Supervisor (Glossary)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Regarding plenums, core construction and fire towers for pre 1945 Hi-Rise:

A

Plenums generally not found Core construction NOT used 38 – 68 All bldgs required to have fire tower. Some prior to 38 have fire tower

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Regarding fire towers and Hi-Rise 45 – 68

A

Fire towers were required in all of these bldgs.

17
Q

Regarding fire towers and core construction for Hi-Rise after 1968:

A

NO fire towers and core construction used extensively.

18
Q

Fusible links have a temperature rating of ___ above the maximum temperature that would normally be found with the system

A

50 F

19
Q

Activation of any detector installed in an HVAC system shall stop the air supply?

A

Into and the return from the affected floor only. Manual pull station sounds alarm on fire floor and floor above

20
Q

Third Stage pumping what gpm at what psi

A

3rd stage 500 gpm @ 700 psi 357

21
Q

Where is the CFRD engine and FAST unit assigned to on a 10-76?

A

They are both assigned to the Fire Sector Supervisor

22
Q

Where does the CFRD engine and FAST unit report into on a 10-77?

A

They will report into the Incident Commander. The FAST Unit and CFR Engine shall be **ASSIGNED **to the Fire Sector when the fire is above the sixth floor. They can be staged on the floor below the fire floor, ready for rapid deployment. At lower floor fires (sixth floor or below) the position of the FAST Unit and the CFR Engine will be determined by the IC.

23
Q

What channel does the Forward Staging Area Manager operate on?

A

The command channel, aide monitors the primary tac.

24
Q

Who does the Fwd Staging area provide support to?

A

The Fire Sector/Branch and the SAE Group

25
Q

Regarding the 10-77 signal the terms “due” and “arrives” are used. Which Chief is referred to as being “due” rather than “arrives”?

A

The 4th due Chief is the safety Chief. An ABC cannot be a Safety Chief. All other Chiefs are assigned as they arrive. The 5th due Chief on a 10-76 is the Safety Coordinator.

26
Q

The Lobby Control Unit will operate on what channel?

A

The Tactical Channel.

27
Q

Who will notify the FAST Truck when additional communication channels are use?

A

The IC must notify the FAST Truck. Not the Dispatcher.

28
Q

What other special unit shall the IC special call, when the ARCS is activiated?

A

The Field Comm Satellite Unit.

29
Q

If the height of the fire floor requires pressure in excess of 250 psi, who must ensure safety zones
are marked off and controlled?

A

The High Pressure Pumping Group Supervisor.

30
Q

The Lobby Control Unit will operate on what channel?

A

The Tactical Channel.

31
Q

The operation, shut down or change of any building system shall not be done without the permission of?

A

The IC or Operation Section Chief. The operation of bldg systems must be done with the assistance of bldg personnel.

32
Q

When is a post fire analysis conducted?

A

A member is killed
An explosion, back draft or BLEVE occurs
A structural failure occurs where a FF was injured
A large loss caused by fire

33
Q

What is a dwarf partition wall? Dunn ch. 21

A

These walls extend only to the underside of the ceiling and do not stop or limit fire spread above the ceiling.

34
Q

According to Dunn what is the most important strategy and tactical consideration at a fire?

A

Water supply and pressure

35
Q

According to Brannigan, what are two examples of Cold Drawn Steel and what temp does it fail?

A

Cables used to brace failing buildings or tendons used in tensioned concrete. 800 F.

36
Q

According to Brannigan, what happens as the length of a beam increases?

A

The beams load carrying capacity decreases proportionately. A 12’ beam can carry ½ the load of a 6’ beam.

37
Q

According to Brannigan, regarding width, when another 2x4 is laid alongside a similar 2x4 what happens to the carrying capacity?

A

It is increased by a factor of 2

38
Q

According to Branningan, regarding depth, what is the difference between a 2x8 beam and a 2x4 beam?

A

A 2x8 beam is twice as deep as a 2x4 beam. The 2x8 has a carrying capacity increased by the square of two or 4 times the carrying capacity of the 2x4.