Building Analysis Functional Requirements Flashcards

FAR, BUILDING EFFICIENCY

1
Q

Typical Efficiency Ratio’s of Building

(Tbl 10.3

A
Offices: 0.75 - 0.85
     Retail offices: 0.75 - 0.9
         Resturants: 0.65 - 0.75
  Public libraries: 0.60 - 0.75 
          Museums: 0.60 - 0.75
           Hospitals: 0.50 - 0.65
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Space requirements for estimated non-assigned spaces

A

Fan Rooms 3-7%
Heat, Boilings Rms 3-5%
Heating forced air 4 -8%
Mechanical Rooms 5-9%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Efficiency Formula of a building

A

Eff. = net area/gross area

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Net Floor Area

A
  • Commonly used spaces also named as “Assignable areas”
  • Measured inside walls
  • Main function/ or mainly used rooms
DOES NOT INCLUDE: 
Circulation
stairways
Elevators
General service areas
Corridors, 
Lobbies 
Restrooms
Custodial rooms
Mechanical Spaces
Electrical and telephone equipment rooms 
Wall and structural thicknesses 
(Kaplan, ppp, 33) (Ballast, 10-14)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Gross Floor Area

A
Assignable and non-assignable areas 
Measured to the exterior face of perimeter walls including all interior walls, columns, and shafts 
-Includes:
Circulation
General service areas
Corridors, 
Lobbies 
Restrooms
Custodial rooms
Mechanical Spaces 
  • Includes patios, decks, other usable open areas that are enclosed on 3+sides and a solid roof
  • SF IS doubled with a ceiling height of 15’ or more (not including stairways with no habitable space above/below
  • Includes any covered areas on/below the first or main floor when the average height is more than 6’ 0”

(Kaplan, PPP, 33) (Ballast, 10-14)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Least efficient space type (based on table 10.3)

A

Hospital 0.50 - 0.65 eff ratio

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Most efficient

A

Overall places of buisness, factories, open warehouses, etc.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Offices efficiency ratio (based on table 10.3)

A

0.75 - 0.85

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Resturant efficiency ((based on table 10.3)

A

0.65 - 0.7

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Public libraries efficiency (based on table 10.3)

A

0.75 - 0.8

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Museums efficiency (based on table 10.3)

A

0.83 - 0.90

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Theaters efficiency (based on table 10.3)

A

0.60-.75

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

FAR (Floor Area Ratio)

A

Gross Area/ Site Area

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Building efficiency

A

Buildign Eff. = Net Area/ grosss area

How well did you know this?
1
Not at all
2
3
4
5
Perfectly