Air Conditioning Flashcards
What are the 4 zones that air temperature can be controlled?
Flight Deck
FWD
Mid
AFT
What bus are the recirculation fans on?
Utility Bus
What recirculation fan works with the Left Pack
Forward
(Aft with Right Pack)
How much extra fuel does an individual pack burn if running in High Flow?
0.3% of total fuel burn
With both engines running, When does a pack go to High flow?
Partner fan fail
With both engines running, What is the relationship between L and R packs if one pack fails?
Remaining pack goes to high flow
What is the relationship between L and R packs if one pack fails?
Remaining pack goes to high flow
What happens to the remaining pack when operating with an engine shut down?
With only 1 engine running the remaining pack is inhibited from going in to High Flow
Air conditioning panel INOP lights are caused by what?
Indicator that individual zone control valve has experienced a fault
Recirc fan INOP light means what?
Fan not working. Refer to logic for why.
How many pack controllers does each pack have?
2 AUTO and STBY
The cargo area is heated to what temperature with?
Approximately 45 degrees F
Which duct supplies air to the cargo compartments?
Aft/bulk cargo come from body duct
Forward cargo comes from centre duct
Which bus supplies power to the Recirc fans?
Utility bus
If carrying live animals, what do we do?
Bulk cargo heat selected to VENT to raise temperature to 65 using additional cabin temperature