AGK Systems - Oxygen Systems Flashcards
When are oxygen masks initiated/deployed
Initiated 14,000 ft
Fully deployed at 1500ft
Flight Crew Oxygen Supply
Supplied from a central store
Oxygen stored at 1800psi
~reduced to 80-100psi for distribution
~Reduced to 8-10 psi at each crew mask
Cylinder is charged via an external charging valve
~Thermal compensator minimises pressure build up
~NRV ensure no flow leaks back through the charging system
Passenger Masks
Regulations require 10% more masks to be installed than seats fitted
CC Portable Oxygen
Alloy steel lightweight cylinder fitted with a combined flow control and pressure reducing valve:
~1800psi charge pressure
~120 litres capacity
Two flow settings:
~Normal: 60 mins at two litres per minute
~High: 30 mins at four litres per minute
Personal Smoke Protection
Last 15-20 minute supply
Flight Crew use googles as well as oxygen masks