1 - Emergency equip, doors, windows Flashcards
Three positions and description of the Emergency (EMER) exit lights switch?
Off - Lights will not work if aircraft electrical power is either selected off or fails
Auto - Lights will turn on if aircraft electrical power (DC) is either selected off or fails
On - all emergency lights illuminate
What does the ACCESS DOORS light mean? the ______ _____ bay or _____ _____ compartment door is not closed latched and locked
forward equipment, electrical equipment
Passenger entry door er armed. Hvað gerist ef þú opnar hana að innan og utan?
Innan: Door powered open and slide deploys
Utan: Door opens but the slide does not deploy
Smoke vent valve selector does what on mask?
Opens the vent valve allowing oxygen to flow to the smoke goggles
If normal electrical power is lost where do some essential cockpit lighting get their power from?
Automatically switched to the Standby AC Bus
How is the emergency lighting system powered and how long does it last?
Remote batteries charged by the aircraft electrical system.15 minutes from a full charge
What happens if the emergency lights switch is not in the armed position? (2)
UNARMED light illuminates and the EICAS’ EMERG LIGHTS
How is passenger oxygen generated?
Chemically
When does the pax oxy deploy? (2)
- Above 14k cabin alt
- Manually by pushing flight deck passenger oxygen switch
Wind limits on aircraft entry and cargo doors?
Do not operate greater than 40kts
Do not leave open with gusts more than 65kts
What does the break away feature on the cockpit door
Allows the door to be forced open in either direction for emergency access or evacuation
Three types of fire extinguishers on board? Where and what for?
- Halon - Flight deck and cabin. Used for electrical, grease, and fuel but can be used for all.
- H2O - Cabin - used for paper, fabric and wood fires only. Not electrical, fuel or grease.
- CO2
When does flight data recorder turn on and how long does it record back to?
Turns on when engines running and records previous 25hrs
Which oxy door when opens starts the flow of oxy to the regulator?
Left door
How turn off the oxygen after masks have deployed?
Close the doors and pull down test/reset switch turns the oxy off