Volume 11: Chapter 2, Section 2 Flashcards
CO monitoring shall take place when (3)____
- CO alarm
- overhaul
- below grade or confined space
CAL/OSHA permissible limits of CO are_____
25ppm
When monitoring for CO a ______ shall be conducted if readings are 25ppm or more
Secondary Reading
When checking for CO, start with the ______point and move to the ________ point
- lowest
* highest
The IC will respond Health Hazmat if (4)
- anyone showing signs
- 25PPM or more
- evacuation
- IC decides
The IC will respond Gas Company if______
25ppm or more
The IC will respond Hazmat Task Force if readings of ______
100ppm or more
For CO residential investigations, record information on Form ______
778 Residential CO Checklist
For CO readings of 100ppm or more respond (3)______
- Gas Co.
- Health Hazmat
- Hazmat Task Force
________ thru the sample are greatly diminishes monitor reading accuracy
Rapid Movement
For best results monitoring CO, slowly trace a _______ pattern in the atmosphere
Diamond
There are more poisoning’s with ______ than any other material
CO
The “Silent Killer” is _______
CO
________ is tasteless, odorless, colorless, non-irritating
CO
The most common sources for CO poisoning are____ and ___
auto exhaust and HVAC systems