Volume 10: Chapter 2, Section 23 Flashcards
A _______ is an external overhanging concealed space, often unsupported, to improve the appearance of the building
facade
A ________ is the continuation of the exterior wall above the roof line
parapet wall
Personnel shall not place themselves under a façade overhang with approval of _______
IC
If a façade must be laddered, a _______ should be used
aerial ladder
Aerial ladders must be placed _______ from the wall
100% + 10 feet
__________ % of the façade interior shall be checked for interior fire spread
100%
__________ shall be used to inspect any portion of the façade that may have fire
inspection holes
A _______ should be placed on the soft side of the façade above the roof line
Heat hole
________ facades are the most dangerous
- add-on
* unsupported
________ can fail in as little as 10 minutes of with direct flame contact
unsupported cantilevered
Optimum ladder placement is on the side_______
without the facade
The ladder shall not rest on the façade and shall be _____ to _____ above the wall
2” – 6”