unit 6-15 PW supply req for ground forces Flashcards

1
Q

engineer officer responsibilities

A

provides sufficient potable water quantities

selection water sources

construct, operate and maintain

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

MDR responsibilities

A

advice CO
assist Engineer Officer
test Halogen and Bacteriological levels

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

what are three influences on water choice

A

quality
quantity
accessibility

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

what are 4 potential water sources

A

public water
surface
ground
bottled

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

types of surface water

A
lakes
streams
river
pond
sea ocean
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

ground water sources

A

wells

springs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

4 methods of water treatment in the field

A

ROWPU
MC lightweight medium tactical
lightweight water purification
tactical water purification system

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

produces 3000 gal water

A

MC lightweight medium tactical

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

125 gal/hour

used to purify for small units

A

lightweight water purifier

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

1500 gal/hour
International Organization Standardization (ISO) compatible
replacing Reverse Osmosis Water Purification Unit

A

tactical water purification system

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

3000 gallon tank

primary means of receiving and storing bulk drinking water

A

portable water storage and distribution system (PWS/DS)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Load handling system (LHS) water tank rack (Hippo) water capacity

A

2000 gallons

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

disinfecting method 1 key points

A
chlorinate to 100ppm FAC
run solution through valves
keep all interior surfaces wet w/ solution for at least 60min
drain into sewer
rinse twice
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

disinfecting method 2 key points

A

water or chemical are in short supply
prepare 5 gallon of water w/ 100ppm chlorine
swap ever 10 min or as necessary to keep walls wet for 1 hours
run solution through valves
drain
rinse twice

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

alternate disinfecting method

A

chlorinate to 100ppmFAC
hold for 24 hours
drain
rinse twice

How well did you know this?
1
Not at all
2
3
4
5
Perfectly