U1 Main Turbine Cooling/SS/LO Flashcards

1
Q

What are the U1 MT Trips?

A

DCS:

  • Condenser Vacuum ≤ 24.1” Hg OR 30 minutes < low setpoint (variable)
  • Overspeed 107%
  • Oil # (Bearing) < 8# for 5 sec ***
  • Low EHC # 1100#
  • Low trip header pressure 2/3 < 800#

Hardwire Trips:

  • AMSAC (activated at > 40% pwr, auctates at < 25% FW flow 3/4)
  • SI
  • SG Hi Hi Lvl at 67% 2/3 on 1 SG (P14)
  • Manual
  • Overall HEA
  • IOPS 110%
  • Stator Water (10 second delay)
    - Low Pressure 36 #
    - Low Flow 499 gpm
    - High Temp 81°C (+ 5 second delay)
  • Thrust Bearing Wear Abnormal > 39 mils (axial)
  • Unit HEA
  • Reactor Trip
  • Emergency Trip
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What auto starts a AC Suction LO Pump on U1?

A
  • Low Suction Press < 10# from the Shaft Driven Oil Pump

- Turbine Trip

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What auto starts a DC Emergency Bearing Oil Pump on U1?

A
  • Low discharge press < 125# from the Shaft Driven Oil Pump WITH Turning Gear oil pp discharge press < 10# ***
  • Turbine Trip
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What auto starts the Turning Gear Oil pump and the DC Backup Oil Pump?

A
  • Bearing Header pressure < 15#

- Turbine Trip

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

When do the Bearing Lift Pumps auto start?

A
  • Auto start on Turbine Low Speed Switch only (Does NOT start on turbine trip)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

When do Bearing Lift Pumps 2 and 4 start?

A
  • Start 20 seconds after Turning Gear engagement to ensure sufficient drag on turbine shaft to prevent the Turning Gear from disengaging
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What are the Bearing Lift Pumps interlocks?

A
  • Interlocked to have Lift Pump suction pressure of > 8# to start Lift Pump
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

When do lift pumps stop?

A
  • Lift Pumps stop when suction pressure < 2#.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Which stop valve allows pre-heating of chest and shell (HPT)?

A
  • # 2 Stop Valve
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

When does the U1 Turning Gear auto engage?

A
  • When the turbine stops (< 1/2 rpm)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What are the U1 Turning Gear interlocks?

A

Will start if:
- 1 oil pump on (Turn Gear Oil, Backup Oil, Emerg Oil)
- Bearing oil # > 25#
- Lift pump disch # > 440# (Except pumps 2 & 4)
- Any lift pump not operation (except 2 and 4)
- Bypass buttons available
for lift pumps and #2 Stop Valve interlocks

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What does the Thrust Bearing maintain and support?

A
  • Limits axial movement of the turbine rotor to prevent stationary and rotating blade contact
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What do the Combined Stop/Intercept valves do?

A
  • Control flow of steam from MSRs to 3 LPTs

- Close on turbine trip to avoid overspeed due to steam in MSRs***

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What are Main Turbine Steam seals supplied by during startup, shutdown, and low load operation?

A
  • 50# Aux Steam (SRV-10 and SMO-10) (Maintains steam seals at 4#
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What are Main Turbine Steam seals supplied by during normal operation?

A
  • Leakage from exhause ends of HP & MFP turbines AND stem leak-off
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Where does SRV-11 dump to?

A
  • 1 A/B heaters
17
Q

How does SRV-10 Fail(Aux Steam supply to Steam Seals)?

A
  • Fails Open
18
Q

How does SRV-11 Fail (Steam Seal Dump Valve?

A
  • Fails closed
19
Q

What are the EHC pump auto starts?

A
Auto 1 - 1450#
   - if run pump goes to status other than run or test
   - 3/3 EHC transmitters fail
   - Auto 1 Test Signal
Auto 2 - 1375#
   - Auto 1 Test Signal
20
Q

What will trip an EHC heater?

A
  • Low Low EHC tank Lvl
21
Q

What will isolated on a Extreme High Lvl in the Gland Steam Condenser?

A
  • CMO-630 (TACW supply valve) will isolate