MSRs Flashcards
1
Q
Where does the U1 MSDTs drain to? **
A
- 5 FW Heaters
2
Q
Where does the U2 MSDTs drain to? **
A
- 4 FW Heaters
3
Q
Where do the RHCDTs drain to during startup for both units?
A
- Main Condenser Drip Receivers
4
Q
Where do the U2 RHCDTs drain to during loaded operations? **
A
- 6 FW Heaters
5
Q
Where do the U1 RHCDTs drain to during loaded operations? **
A
- 6 FW Heaters
6
Q
Where do the MSR 2nd pass drains for both units go to?
A
- RCDTs then to 6 FW heaters
7
Q
Where do the MSR 4th pass drains for both units go to?
A
- 6 FW heaters
8
Q
How do the Reheater MRV and MMO Steam Supply valves respond on a turbine trip for both units?
A
- All steam supplies to MSRs Auto Close on a Turbine Trip
9
Q
When will the crosstie valve between drain headers to 6A/B FW Heater open?
A
- Auto opens if either drain valve not full open
Auto closes when both drain valves are full open