What is the normal Lvl, temp, and # of the PRT? **
- 100°F
- 83%
- 3#
When will the PRT vent valve not open?
- If # is > 10#
What is the max # of the PRT?
- 100# (Rupture Disk)
What is the PRT designed to do?
- Condenses 110% of Pzr steam space
- Protects the Rx Vessel against brittle fracture during LTOP conditons
- Provides overpressure Protection
What are the inputs to the PRT?
- Pressurizer Safeties and PORVs
- Seal Water Return Safety
- CCP Suction Safeties
- ECCS Safeties
- RHR Suction Safety
- RHR Hot Leg Discharge Safety
- RHR hx Safeties
- PW and N2
What conditions are the Pzr Lvl and # Ctrl designed to accommodate?
Designed to accommodate:
- unit load change @ 5% / minute.
- Instant load changes @ 10% w/ auto rod control.
- step load reduction @ 50% w/ auto rods and dumps
What is the lvl per percent in the Pzr?
- 75gal/1% **
What is the Pzr Lvl Program based on?
- Based on Auctioneered High Tave
- Unit 1 - 22% to 50% (28% diff)
- Unit 2 - 22% to 55% (33% diff)
- Both Units Trip at 92% (2/3)
At what pressure do the Pzr Safeties lift?
- 2485# (SV-45A/B/C)
At what pressure do the Pzr PORVs open?
- 2335# (NRV-151/152/153) **
Which Pzr PORVs have backup air bottles?
- NRV-152/153
What supplies the PRT with water if it needs to be filled or if it gets > 126°F during normal ops?
- PW
Which Safeties and PORVs have acoustic monitors?
- Safeties- 1 monitor for each safety valve (3 total)
- PORVs- 1 monitor total (combined)
What is the Pressurizer Lvl Rx Trip?
- 92% Pzr Lvl
What are the Pzr Spray Bypass valves for?
Allow continuous flow for:
- PZR boron concentration same as RCS
- Minimize PZR temp stratification
- keep spray lines equilibrium with RCS loops.