SOG 28-03 NATURAL GAS EMERGENCIES Flashcards

1
Q

According to SOG 28-03 Natural Gas Emergencies What is the recommended distance for staging additional apparatus in a natural gas emergency?
a. 50 meters
b. 75 meters
c. 100 meters
d. 125 meters

A

c. 100 meters

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

According to SOG 28-03 Natural Gas Emergencies In a natural gas emergency, why is it essential to confirm the presence of a gas leak?
a. To determine the weather conditions
b. To assess the explosive risk
c. To notify the media
d. To activate the fire alarm

A

b. To assess the explosive risk

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

According to SOG 28-03 Natural Gas Emergencies What should personnel use to determine the concentrations of natural gas in the air during an emergency?
a. Smoke detectors
b. Thermal imaging cameras
c. 4-gas detector
d. Oxygen masks

A

c. 4-gas detector

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

According to SOG 28-03 Natural Gas Emergencies When dealing with a confirmed natural gas leak, what action should personnel take regarding communication?
a. Silence communication to avoid panic
b. Maintain communication at all times
c. Communicate only with the gas company
d. Communicate through written messages

A

b. Maintain communication at all times

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

According to SOG 28-03 Natural Gas Emergencies What is the primary purpose of using personal protective equipment (PPE) in areas requiring it?
a. Comfort
b. Compliance with regulations
c. Aesthetics
d. Safety

A

d. Safety

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

According to SOG 28-03 Natural Gas Emergencies What should personnel do to prevent escaping gas from entering buildings, sewers, or vaults?
a. Open all doors and windows
b. Close all doors and windows
c. Use fans to blow the gas away
d. Use fire extinguishers

A

b. Close all doors and windows

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

According to SOG 28-03 Natural Gas Emergencies What is the recommended tactic when facing a natural gas fire with no immediate threat to life or property?
a. Extinguish the fire immediately
b. Evacuate the area
c. Exposure protection
d. Call the gas company

A

c. Exposure protection

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

According to SOG 28-03 Natural Gas Emergencies What should personnel avoid doing when attempting to control a natural gas leak in excavations?
a. Use water to control the leak
b. Enter the excavation
c. Introduce ventilation
d. Attempt to stop the leak on a plastic pipe

A

b. Enter the excavation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

According to SOG 28-03 Natural Gas Emergencies What action should personnel take if there is a need to eliminate open sources of ignition in a natural gas emergency?
a. Allow the use of on/off switches
b. Use electrical equipment freely
c. Restrict the use of on/off switches, appliances, lights, and phones
d. Ignore ignition sources

A

c. Restrict the use of on/off switches, appliances, lights, and phones

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

According to SOG 28-03 Natural Gas Emergencies What is the primary consideration when using the outside shut-off valve in a natural gas emergency?
a. Use it immediately without caution
b. Be aware that shutting it off may interrupt important production processes
c. Use it only if there is no gas technician on site
d. Use it only for residential buildings

A

b. Be aware that shutting it off may interrupt important production processes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

According to SOG 28-03 Natural Gas Emergencies What is the recommended method for ventilation in a natural gas emergency?
a. Pressurize the area with any available equipment
b. Use intrinsically safe equipment or ventilate naturally
c. Use non-intrinsically safe equipment for quick ventilation
d. Ignore ventilation as it may worsen the situation

A

b. Use intrinsically safe equipment or ventilate naturally

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

According to SOG 28-03 Natural Gas Emergencies What action should personnel avoid during a natural gas emergency involving a plastic pipe?
a. Attempting to stop the leak
b. Using water to control the leak
c. Closing off the shut-off valve
d. Evacuating the area

A

a. Attempting to stop the leak

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

According to SOG 28-03 Natural Gas Emergencies What should personnel do once the gas company is on the scene during a natural gas emergency?
a. Assume control and manage the situation independently
b. Work in coordination with the gas technician
c. Evacuate the area immediately
d. Ignore the presence of the gas company

A

b. Work in coordination with the gas technician

How well did you know this?
1
Not at all
2
3
4
5
Perfectly