nursing ops - direct option Flashcards

1
Q

Large diameter hose is what dimension or larger

A

4” or greater

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What distance from fire hydrant to structure is required to be considered a non-hydrant area

A

2000 feet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What is the minimum fill rate & pressure for a tanker

A

1000 GPM at 100 psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What is the max distance between relay pumpers

A

1000 feet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What is the max distance for a relay operation

A

1 mile

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Rule of thumb what distance should I really be turned into a shuttle operation

A

3000 feet or requiring greater than three engines

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Tanker task force

A

Three tankers
one engine
one commander

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Dry hydrantsRequire what size female couplings

A

4 1/2 inch to 6 inch double female
6 inch double female

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Drafting pits
AKA dump tanks

A

1500-3000gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Low level suction strainer

A

Used in dump tanks
can be used in 2 inches of water
Max flow 750 gallons per minute

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Low profile jet siphon strainer

A

Allows engine to get water from dump tank without drafting

utilizes Venturi affect
minimum flow 500 GPM

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

jet siphon

A

moves water between dump tanks 800 GPM flow rate
utilizes Venturi affect

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

First engine nursing ops direct fill role and responsibility

A

Less than 200’ - lays out supply line and acts as attack engine

200’-1000’ - proceeds directly to incident and begins attack

    2nd engine will layout
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

First tanker nursing ops direct fill role and responsibility

A

Less than 200’ - position at dumpsite serve as dumpsite tanker

200’ - 1000’ positions near first engine. connects to lay out and supplies first engine

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Second engine nursing ops
direct fill role and responsibility

A

Less than 200’ - transfer water to first tanker at dumpsite join shuttle if needed
200’ - 1000’ - lays out supply line from
dumpsite to first tanker

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Second tanker nursing ops direct fill role and responsibility

A

Less than 200’ - transfer water to first tanker at fill site join shuttle if needed

200’ - 1000’ dumpsite tanker

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Third engine nursing ops direct fill role and responsibility

A

less than 200’ - positions with 1st tanker and assists

200’-1000’ - dumps water joins shuttle

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

Fourth engine nursing ops direct fill role and responsibility

A

Dump water at dumpsite join shuttle

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Fifth engine nursing ups direct fill role and responsibility

A

fill site operations

minimum two lines

20
Q

Goals of rural water supply operations

A

Rapid- deployment
efficient- movement of water expandable - water supply
uninterrupted/ flow of water

21
Q

Define direct fill operation

A

nursing operation providing immediate water to the fire ground eliminating needs for portable thumbtacks

short driveways less than 200 feet the second tanker will transfer water from to first tanker and then become part of the shuttle operation

Long driveways long more than 200 feet the second tanker will position to receive water from the Shuttle operation. first tanker proceeds to the structure with first arriving engine

22
Q

Define nursing operation

A

Procedure during initial fire attack used in place of dumpsite first arriving engine and tanker position at fire location for attack additional tanker establishes dumpsite supplying water to attack apparatus

23
Q

Define nurse tanker

A

Tanker which proceeds with the initial attack engine to the incident and provides water as needed at attack

24
Q

Define relay operations

A

Uses three or fewer engines to supply the attack engine directly from the water source to the supply line

25
What distance in feet should I relay operation not exceed
3000’
26
Define shuttle operation
The procedure of using engines and tankers remove water from a full site to the incident scene
27
What is the nova recommendation for a tanker size
1000 gpm 2000 gallon tank
28
What is the calculation for determining tanker flow
tank capacity - 20% ————————— round trip time
29
nursing operations direct fill option What is the first engines drivers responsibility When dumpsite is less than 200 feet from incident
layout hose line and Drive directly to fire location
30
nursing operations direct fill option What is the first tanker drivers responsibility When dumpsite is less than 200 feet from incident
Position at dumpsite out of route of travel & supply attack engine
31
nursing operations direct fill option What is the 2nd engines drivers responsibility When dumpsite is less than 200 feet from incident
Transfer water to first tanker become part of shuttle operation
32
nursing operations direct fill option What is the 2nd tanker drivers responsibility When dumpsite is less than 200 feet from incident
Transfer water to first tanker at dumpsite become part of water shuttle operation
33
nursing operations direct fill option What is the 3rd engines drivers responsibility When dumpsite is less than 200 feet from incident
Transfer water to first Tanqueray dumpsite become part of the shuttle operation
34
nursing operations direct fill option What is the 4th engines drivers responsibility When dumpsite is less than 200 feet from incident
Transfer water to first tanker dumpsite and become part of shuttle operation
35
nursing operations direct fill option What is the 5th engines drivers responsibility When dumpsite is less than 200 feet from incident
Respond to fill site location establish water supply and lay at least two lines to facilitate rabbit feeling of units
36
nursing operations direct fill option What are the additional alarm units drivers responsibility When dumpsite is less than 200 feet from incident
Dump water at dumpsite enjoin shuttle operation
37
nursing operations direct fill option What is the 1st tanker drivers responsibility When dumpsite is more than 200 feet from incident
Proceed with first engine to the incident scene and supply water to the first engine
38
nursing operations direct fill option What is the 2nd engines drivers responsibility When dumpsite is more than 200 feet from incident
Layout from dumpsite to the first tanker and prepared to supply water to the tanker
39
nursing operations direct fill option What is the 2nd tanker drivers responsibility When dumpsite is mire than 200 feet from incident
Position out of route of travel at dumpsite connect to 4 inch Siamese and supply second engine repair to service direct fill tanker at dumpsite
40
nursing operations direct fill option What is the 3rd engines drivers responsibility When dumpsite is more than 200 feet from incident
Transfers water to tanker dumpsite joins shuttle operation
41
nursing operations direct fill option What is the 4th engines drivers responsibility When dumpsite is more than 200 feet from incident
Transfer water to tanker at dumpsite join shuttle operation
42
Dry hydrants should be back flushed and tested how often
every 6 months
43
What to adapters do units need for dry hydrants
4 1/2” to 6” double female 6” double female
44
How often should storage tanks of subdivisions neighborhoods be checked for proper operation
Every six months
45
What is the diameter of hard suction sleeve hose on engines
6”
46
What is the preferred method for a continuous water supply during rural water supply operations
Nursing/direct fill method and utilizing a tanker to nurse the attack engine
47
What are the four goals of rule water supply operations
rapid deployment support of initial attack efficient water supply expandable water supply ops Uninterrupted flow of water supply