IFSTA 15 Apparatus testing Flashcards

1
Q

What are the two types of testing for apparatuses

515

A

Pre-service test and performance tests

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Define preservice tests

A

Driver operator usually not involved,
but may assist

types of tests include
Manufacture
pump certification
acceptance

NFPA standards generally used

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

How often are performance tests Performed

A

On an annual basis and after major repairs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What characteristics are included in the manufacturers portion of a pre-service test

A

Road test

hydrostatic test

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What acceleration standard is used for the road test within 25 seconds

A

Accelerate to 35 miles per an hour within 25 seconds

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What is the maximum top speed that must be achieved during the road test

A

50 mi. per an hour

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

At what speed and distance must and apparatus come to a stop during the road test

A

20mph stop in 35’

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What is the standard of the hydrostatic test during the manufacturers testing portion

A

Tank fill, tank to pump, valves are subjugated to a minimum hydrostatic test of
500 psi for a minimum 10 minutes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

NFPA 1911

A

standard for inspection, maintenance & testing

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

site consideration for pump performance testing at draft

A

Distance from centerline of pump intake above surface water will be based on capacity

1500 GPM or less 10 feet
2000 GPM 6 feet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What range of air temperature should exist when performing pumper performance test

A

0 - 110

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What range of water temperature should exist when performing pumper performance tests

A

35-90

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What minimum barometric pressure (inches of mercury) should exist during pumper performance testing

A

29” of mercury

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What is the minimum diameter of hose line to be used while conducting pumper performance test

A

2 1/2”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

During testing if A mark on a hose coupling moves more than —— amount of inches from the coupling testing should stop and replacement of hose should occur

A

3/8”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Define net pump discharge pressure

A

Difference between intake pressure and discharge pressure

17
Q

At what psi intervals is the pump tested at during performance testing

A

150
165
200
250

18
Q

All gauges used for service testing must be calibrated within how many days of testing

A

60

19
Q

During testing if a flowmeter is not being used what type of nozzle must be attached to the hose

A

smoothbore

20
Q

During testing if a flow meter is used what type of nozzle may be attached to the hose

A

smoothbore or fog

21
Q

during testing, the flow meters used must be + or - what percent accuracy

A

5%

22
Q

which test is generally conducted first while conducted performance evaluations

A

vacuum test

23
Q

how many inches of mercury must be achieved during vacuum testing

A

22”

24
Q

fire pumps of 1250 gpm and 1500 gpm must achieve a prime within how many seconds

A

1250 - 30 seconds or less

1500 - 45 seconds

25
Q

pumpers with a tank capacity of 500 gallons or less must be capable of flowing how many gpm

A

250

26
Q

pumpers with a tank capacity greater than 500 gpm must be capable of flowing a minimum of

A

500 gpm

27
Q

if an apparatus achieves less than 90% of its original rated capacity what 2 options exist

A

may be removed from service & repaired

be given a lower rating

28
Q

true or false, NFPA 1911 requires foam proportioning devices to be tested on an annual basis

A

false

29
Q

what 4 methods are used to test foam proportioning equipment

A

displacement method
pump discharge volume method
solution refractivity method
solution conductivity method

30
Q

what does concentrate displacement method test

A

accuracy of volume of concentrate drawn through system

31
Q

what does pump discharge volume method test

A

direct injection systems

32
Q

define refractometer

A

measures amount of foam concentrate in the solution. using light velocity like x ray