IFSTA 12 Relay Pumping Flashcards
define relay operation
3rd 425
Two or more pumpers used to move water over a long distance by operating series also known as relay pumping
define large diameter hose
3rd 427
3 1/2 inch to 6 inches in diameter
what considerations are taken to determine the need of a relay pumping operation
3rd 427
Total volume of water needed
distance between incident scene and water source
fire department pumpers are ready to flow their maximum volume at what pressure
3rd 429
150 psi
pumpers are rated to flow 70% of their max volume at what pressure
3rd 429
200 psi
fire department poppers are rated the flow 50% of the maximum volume at what pressure
3rd 429
250 psi
The overall capacity of a relay operation system is determined by what
3rd 432
Apparatus for the smallest pump and the smallest diameter of hose used in the relay
attack engines should set their pressure governors in what mode during a relay operation
3rd 433
Pressure mode
source and relay pumpers should set their pressure governors to what mode during a relay operation
3rd 433
RPM mode
For relay pumpers equipped with adjustable intake relief valves how many psi above the static pressure of the water system should they be set
3rd 434
10
attack pumpers equipped with adjustable intakes should have them set at what range
3rd 434
50-75 psi
define open relay method
3rd 435
Method of relay pumping where portable folding tanks are deployed at each intake for pumpers in the relay operation. operating from the portable tank eliminates the pressure surges and inconsistent supplies