- Ground-fault circuit interrupter protection must exist in:
a. Kitchen countertop receptacles
b. Bedroom receptacles
c. Hallway receptacles
d. All of the above
Kitchen countertop receptacles
- An inspector’s license was reprimanded and he was penalized for failing to protect the public against fraud, misrepresentation or unethical practices in the field of real estate and/or inspection business while associated with him. Look up for factual understanding…
a. $1,000
b. $5,000
c. $10,000
d. $500
1,000
- Inspectors shall not accept employment to repair, replace, maintain or upgrade systems or components of properties practice on which the inspector has performed an inspection under a real estate contract, lease, or exchange or months of the date of the inspection.
a. 0
b. 6
c. 10
d. 12
12
- The inspector is required to?
a. Report systems that do not operate properly using normal controls
b. Inspect humidifiers
c. Inspect and report on heat exchangers
Report systems that do not operate properly using normal controls
- The inspector is not required to report:
a. As in need of repair, a crawl space that is not adequately ventilated
b. The type of foundation
c. Anything that is not accessible
d. As in need of repair, any post tensioned cable ends that are not protected
Anything that is not accessible
- The inspector is not required to:
a. Report roof covering that is not appropriate for the slope of the roof
b. Report the type of roof covering
c. Determine the remaining life expectancy of the roof covering
Determine the remaining life expectancy of the roof covering
- An inspector shall exclude from the inspection any part, component or system which the inspector is not competent or qualified to inspect.
a. True
b. False
True
- The inspector is not required to?
a. Report deficiencies in material used for venting systems
b. Determine type of material contained in insulation, wrapping of pipes, ducts, jackets
c. Report flue or vent pipes that do not properly terminate
Determine type of material contained in insulation, wrapping of pipes, ducts, jackets
- An inspector must include in the report all components or systems that are found in a home.
a. False
b. True
True
- Inspector is not required to?
a. Report the need of repair missing or damaged window and door screens
b. Report the need of repair damaged glazing in windows and exterior doors
c. Determine the presence of, or extent or type of insulation or vapor barrier in exterior walls
Determine the presence of, or extent or type of insulation or vapor barrier in exterior walls
- The inspector is required to?
a. Test for quality and volume of well water
b. Inspect fire sprinkler systems
c. Report deficiencies in functional drainage
d. Inspect water softeners
Report deficiencies in functional drainage
- The inspector is not required to report on?
a. Visible evidence of moisture penetration
b. Efficiency, adequacy, or capacity of the system
c. Inadequate attic space ventilation
d. The approximate depth of insulation, where visible
Efficiency, adequacy, or capacity of the system
- The inspector is not required to report?
a. Conditions of paint stains or other surface coatings
b. As in need of repair, damaged glazing in windows
c. Safety glazing in hazardous materials
Conditions of paint stains or other surface coatings
- The inspector does not have to inspect appliances?
a. False
b. True
False
- The inspector needs to report?
a. Condition and presence of storm windows
b. Any locks on exterior door that do not operate
c. Any locks on interior doors that do not operate
Any locks on exterior door that do not operate
- The inspector is required to?
a. Report if he/she deemed the furnace to be inaccessible
b. Determine the adequacy of heating systems
c. Operate steam heat systems
d. Program digital-type thermostats
Report if he/she deemed the furnace to be inaccessible
- The inspector is required to report on?
a. Deficiencies in combustion air vent
b. All answers correct
c. Gas leak
d. Gas log lighter valves that do not function
All answers correct
Deficiencies in combustion air vent
Gas leak
Gas log lighter valves that do not function
- The balusters of a deck less than 30” off the ground must have no more than 4” between them.
a. False
b. True
False
- The inspector is not required to?
a. Report switches that are not in safe locations or do not operate
b. Inspect self-cleaning functions of appliances
c. Report as in need of repair, unusual vibration levels of power vents
Inspect self-cleaning functions of appliances
- An inspector must include in the report all components or systems that are found in a home.
a. False
b. True
False
- The inspector is not required to report?
a. The adequacy of the draft
b. Fireplace dampers that do not work
c. Absence of non-combustible heart extension
The adequacy of the draft
- According to the TREC SOP, the inspector must report the method used to inspect the roof, if the inspection is performed from other than a roof level
a. False
b. True
True
- The inspector shall operate the cooling system when the outside temperature is greater than 55 degrees.
a. False
b. True
False
- The inspector shall report the type of cooling system.
a. False
b. True
True
- The inspector is required to?
a. Report in need of repair, a shower enclosure that leaks
b. Inspect system that has been shut down
c. Operate plumbing shut-off valves
Report in need of repair, a shower enclosure that leaks
- The inspector is not required to?
a. Report cracks in the commodes
b. Report supply and drain pipes that leak
c. Operate free standing appliances such as microwaves
Operate free standing appliances such as microwaves