Jim's Practice Test 3 Flashcards
A chimney should generally be installed?
a. 6” higher than anything within 10’
b. 18” higher than anything within 10’
c. 2’ higher than anything within 10’
d. 3’ higher than anything within 10’
2’ higher than anything within 10’
The hearth of a fireplace should extend in front inches, if the opening is under 6’ and
inches if over 6’:
a. 20” & 20”
b. 16” & 20”
c. 16” & 16”
d. Does not matter
16” & 20”
Clay/Concrete tile roofs should have how much overlap:
a. 6”
b. 3”
c. 10”
d. 12”
3”
A built-up roof having a lap joint every 12” is a:
a. 3-ply
b. 6-ply
c. 2-ply
d. None of the above
3-ply
Wood shakes and shingles are best maintained by:
a. Applying a quality waterproof sealer periodically
b. Applying a quality oil base paint annually
c. Allowing them to age naturally
d. Washing annually with bleach to remove mildew
Applying a quality waterproof sealer periodically
What is the appropriate insulation for a built-up roof?
a. Fiberglass
b. Cellulose
c. Mineral wool
d. Rigid
Rigid
What is the term used to describe the act of enlarging/offsetting the chimney as it goes through
the roof?
a. Capping
b. Spackling
c. Corbeling
d. Wythe
Corbeling
A crack in the bricks at the top of a doorway or window usually indicates:
a. Water leak
b. Improperly mixed mortar
c. A short or rusted lintel
d. No vapor barrier in the insulation
A short or rusted lintel
Resistance is measured in:
a. Volts
b. Watts
c. Amperes
d. Ohms
Ohms
Romex is another name for what type of cable:
a. AC
b. BX
c. IMD
d. NM
NM
Current flow is measured in:
a. Volts
b. Watts
c. Amperes
d. Ohms
Amperes
A non-grounded receptacle within 6’ of water should be replaced with a:
a. GFCI receptacle
b. GFCI upstream from receptacle
c. Single pole GFCI breaker
d. All will be ok
All will be ok
If the black wire or hot wire carries 10 amps, how much does the white or neutral
wire carry:
a. Half of the black wire
b. Same as the black wire
c. Twice as much as the black wire
d. It is neutral (has no amps)
Same as the black wire
When converting from natural gas to propane gas:
a. The orifice must be larger
b. The orifice plays no role
c. The orifice must be smaller
d. None of the above
The orifice must be smaller
The devices used to provide ignition for oil and gas-fired systems are
a. Thermostat controls, dampers and emergency shut offs
b. Blower, motor, fan and limit switches
c. Emergency flashing lights and low limit switches
d. Pilot/electronic ignition and sensing devices
Pilot/electronic ignition and sensing devices