- Picture a panel with 8 fuses. Four have black wires, 4 have white wires. Pick the most accurate statement:
a. Fused neutrals
b. 240 volt fuses
c. Never a problem
d. Always a problem
Fused neutrals
- Three wires to masthead, 2 wires to main panel; what is voltage:
a. 240 volts
b. 120/240 volts
c. 120 volts
d. 100 amps
120 volts
- The best way to vent and insulate a cathedral ceiling:
a. Fill cavity completely
b. Leave gap above insulation
c. Always use fiberglass batts
d. Use soffit vent only
Leave gap above insulation
- Which is the most rigid floor joist:
a. 2x10
b. 4x8
c. 2x12
d. 4x4
2x12
- Common Temperature Rise with an old furnace:
a. 70º- 100º
b. 150º- 180º
c. 30º- 60 º
d. 25º- 45º
70º- 100º
- Where roof and dormer come together, siding should be ” above shingles:
a. Makes no difference
b. 3”
c. 1-2” above shingles
d. 1/2”
1-2” above shingles
- Vapor barrier should be:
a. To the cold side
b. To the warm in winter side
c. To either side
d. Depends on where installed
To the warm in winter side
- Shingles are 4 years old, cupping of tabs, with no loss of granules. Cause is:
a. Defective shingles
b. Poor installation
Defective shingles
- Water heaters must have a:
a. Pressure relief valve
b. Temperature/pressure relief valve
c. Magnesium anode rod
d. Temperature relief valve
Temperature/pressure relief valve
- The relief valve for a water heater must be installed:
a. With stem directly in tank (top 6”)
b. With stem in tank or hot water pipe
c. Only in hot water pipe
d. None of the above
With stem directly in tank (top 6”)
- Wall cracks should be investigated to determine if structural rot, structural cracking, foundation settlement or pulled fastenings have occurred if crack is wider than:
a. 1/8”
b. 1/4”
c. 3/8”
d. 1/2”
1/4”
- Plaster cracks over a chimney breast are usually caused by:
a. Changing materials
b. Settlement of the chimney
c. Heat
d. Changing of humidity from front to back
Settlement of the chimney
- When plaster cracks appear over gypsum lath either 2 or 4 feet apart, this is normally:
a. Not serious
b. The last sign before the wall or ceilings fall
c. Uncommonly heavy storage in attics or 2nd floors
d. A sign of poor workmanship
Not serious
- What is the possible result of water ponding on a roof?
a. Attracts ducks
b. No effect
c. Reduced life expectancy
Reduced life expectancy
- The most obvious clue to a plumbing venting problem is:
a. Gurgling
b. Poor water flow
c. Water hammering
d. Sewer odor
Gurgling
- What is the minimum extension above the roof line of a vent pipe to prevent frost closure?
a. 2” or 3”
b. 6” above snow line
c. 10” above roof
d. 2” or 12”
6” above snow line
- What size copper wire is required for 40, 30, 20, 15 amp breakers:
a. 8, 10, 12 14
b. 14, 12, 10, 8
c. 10, 12, 14, 16
d. 6, 8, 10, 12
8, 10, 12 14
- Sub-panels require neutrals and grounds to be separated and isolated. What is another term for this?
a. Floating neutral
b. Floating ground
c. Ungrounded
d. Bonding
Floating neutral
- Where should collar ties be attached to the rafter:
a. Nearer the top
b. Nearer the middle
c. Nearer the bottom
d. Doesn’t matter
Nearer the middle
- No trap in basement drain. You should tell the client:
a. It’s okay, it’s in the basement
b. Advise to get repaired
c. Say germs will grow
d. Rodents will enter
Advise to get repaired
- Which roof covering has the greatest life expectancy:
a. Asphalt
b. Clay tile
c. Slate
d. BUR
Slate
- Where would you not typically find condensation:
a. Attic
b. Windows
c. Basement
d. Interior bedroom
Interior bedroom
- Basement leaks often occur because:
a. Missing gutter downspout extensions
b. Poor grading
c. Lack of control of roof and surface water
d. All of the above
All of the above
Missing gutter downspout extensions
Poor grading
Lack of control of roof and surface water
- During heat pump operation, supplemental heat may be provided by:
a. Ground loop heat source
b. Electric heat strips
c. Solar panels
d. All of the above
Electric heat strips
- When inspecting a heat pump or air conditioner, you find the inside coils condensation drain is connected directly to, or is inside of a sanitary sewer line:
a. This is ok and you do not report it
b. This is a health and safety concern and it needs to be corrected
c. This is not right, but is such a minor detail that you do not report it
d. None of the above
This is a health and safety concern and it needs to be corrected
- A hole drilled through a joist for plumbing or electrical should be located at/in the:
a. Center
b. Bottom
c. Top
d. Doesn’t matter
Center
- Rot/mildew/fungus can begin in moisture levels of:
a. 10%
b. 20%
c. 30%
d. 40%
20%
- An engineered floor joist requires squash blocks:
a. Only if the span is greater than 16’
b. Only if the span is greater than 12’
c. At all bearing points
d. As required by manufacturer
As required by manufacturer
- FRT plywood failure is due to:
a. Too much ventilation, which actually drew in moisture and created a condition of acid hydrolysis
b. Inadequate ventilation, accompanied by high heat and humidity
c. Was installed and shingled over when wet
d. Galvanic reaction from the fasteners
Inadequate ventilation, accompanied by high heat and humidity
- Which of the following statements is true regarding a hillside house with a foundation drain systems:
a. Rock-filled curtain drains or diverter drains are not allowed on the interior side of the foundation.
b. The roof drains should connect directly to the footing drains and have cleanouts.
c. All foundation drain systems must be in perforated plastic piping extending to daylight.
d. The foundation drain systems collect water passing laterally through the slope.
The foundation drain systems collect water passing laterally through the slope.