L-4 Flashcards
Describe the fuel conditioning limits less than 50% power?
When fuel conditioning limits are relaxed, are there any other limits that apply? If so what are they? Why?
Describe the fuel conditioning limits concerning the control rods?
< or = 50%, no fuel conditioning limits exist
yes, an admin limit of 5 MW/ min, minimize effects of Xenon oscillations on delta I
- 3 steps / hr when:
- withdrawing above previously reached position in s/u. OR
- power above conditioned power level
(minimize local power increases)
When a reactor is achieving initial criticality and power ascension to 100% power what if any limitations are there on power increase > 50% power?
Describe
yes, 3% / hr until fuel is conditioned
conditioning requires:
- being maintained at given power for 72 hrs in 7 day period
- once conditioned no limits apply
- fuel keeps conditioning for 27 days
(significantly reduces probability of fission product release from fuel to coolant if flaw exists)
What T.S. Must be met prior to exceeding 50% power?
QPTR
AFD
What adverse problems exist with long life cores?
Axial flux anomilies
rods failing to insert (bowed guide tubes)
clad corrosion
When ramping from 2-30% power what three indicators should be cross referenced to ensure reasonable agreement?
When swaping from sequential to single valve mode, what feedbacks should be in?
- PR NI’s
- IR NI’s
- loop delta T’s
- MW feedback
- IMP feedback