Chapter 15 - Appartus Testing Flashcards
The two basic categories of testing are grouped as __________ and ___________ tests.
preservice and performance
p 515
Which three NFPA standards are commonly used as a basis for most apparatus bid specifications?
NFPA 1901 - Standard for Automotive Fire Apparatus
NFPA 1906 - Standard for Wildland Fire Apparatus
NFPA 414 - Standard for Aircraft Rescue and Firefighting Vehicles
p 516
The _______ _______ is to be conducted with the vehicle loaded to the same weight as it will be when placed in service.
road test
p 516
- Preservice apparatus maneuverability tests designed to determine the road worthiness of a new vehicle.
Road Tests
p 516
Road Test
- The apparatus must accelerate to ____ mph from a standing start within ____ seconds. The test is conducted in two runs in opposite directions.
35 mph / 25 seconds
p 516
Road Test
- The apparatus must achieve a maximum top speed of ____ mph. This requirement may be waived for vehicles not designed for use on public roadways.
50 mph
p 516
Road Test
- The apparatus must come to a full stop from _____ mph within ____ feet.
20 mph / 35 feet
p 516
If special requirements are sought from the apparatus manufacturer, the purchaser should write them into the bid specifications as ____________ ___________ as opposed to engineering or equipment specifications.
performance requirements
p 516
A ____________ test is performed to ensure that the pump and associated piping are capable of withstanding high pressure pumping demands.
hydrostatic test
p 517
The pump body as well as the entire intake and discharge piping system, with the exception of the tank fill and tank-to-pump lines on the tank side of the valves, are subjected to a minimum hydrostatic test pressure of ______ psi of a minimum of ____ minutes.
500 psi / 10 minutes
p 517
______ ___________ tests are performed by an independent testing organization such as Underwriters Laboratories, and are designed to ensure that the fire pump will operate as designed on the completed apparatus.
Pump certification
p 517
For apparatus equipped with an onboard water tank, a ______-____-______ flow test must also be performed.
tank-to-pump
p 517
- Procedure used to determine the rate of water flow available for fire fighting at various points within the distribution system.
Fire Flow Testing
p 517
______________ testing is conducted to demonstrate to the purchaser that the apparatus conforms to all bid specifications at the time of delivery.
Acceptance testing
p 517
The requirements for fire department service testing are contained in NFPA ?
NFPA 1911 - Standard for the Inspection, Maintenance, Testing and Retirement of In-Service Fire Apparatus