Case Study - Commercial refurb Flashcards
What was the roof construction?
Timber joists covered with plywood and felt
Did you carry out core tests to the roof to determine its construction and the presence of water if not why?
No - the client advised on the general construction following previous remedial work and there were no reported leaks internally. It was decided to review upon removal of the felt
You say the roof covering had numerous tears and blistering but there is no mention of any indications of water ingress into the building-why?
There were no reported leaks internally through there was of course a risk of concealed defects. Repairs had been carried out on a frequent basis.
How did you allow for repairs to the roof deck?
There was a provisional sum to cover deck repairs
Is part K of the Building Regulations retrospective?
No - The regulations apply to new construction work, and do not require that existing buildings are brought up to standard. However, where new work is being carried out to existing buildings, such as alterations, insulation and so on the regulations do apply. The regulations may also apply if the use of a building is changed.
How would the handrail be fixed to the roof?
The handrail was freestanding, stability is provided by cantilever counter balance weights
What legislation, apart from the HSAW applied to your roof survey?
the Health and Safety at Work etc Act 1974;
the Work at Height Regulations 2005;
Construction (Design and Management) Regulations 2015;
What is the recommended distance from the unprotected edge you need to be?
I would risk assess it based on environmental conditions but generally 2m
You recommended a monocouche render for the south facing walls-why as these renders are prone to cracking?
I considered silicone based and acrylic render but this was more expensive, acrylic render is not breathable
What other types of renders may have been more suited and why did you reject them?
Lime but this was dismissed as more labour intensive
Silicone but this was more expensive
Cement and acrylic not considered breathable
How did you deal with the residents right “ to quite enjoyment” when removing the render?
Through notification and communication to agree “noisy” work hours
You suggest that the external walls may have been damp due to the faulty render. If so, what advice did you give to your client about their potential liabilities under the Landlord and Tenant Act 1985
I advised that the Landlord and Tenant Act 1985, section 11 states that the freeholder is responsible for maintaining the exterior and structure of the building in good repair and that they should seek advice on liabilities from their RICS registered managing agent.
What advice did you give to your client about their liabilities for any internal repairs to the individual flats?
I advised that they may be responsible for internal repairs under the Landlord & Tenant Act 1985 and that they should seek advice on liabilities from their RICS registered managing agent.
Did your PI insurance cover you to give advice on fire safety matters?
No advice was given other than to seek advice from a competent specialist Fire Risk Assessor
What other legislation may have required emergency lighting?
British standards and Approved Documents