Book 2 Chapter 33: Internal Combustion (IC) Engine Gen-Sets Flashcards

1
Q

The alternator output must be the same as that of the system relative to which of the following?
A) The phase sequence must be the same
B) The phase must be the same
C) The frequencies must be the same
D) All of the above

A

D) All of the above

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Temperatures are very important, and sometimes the cooling system includes a __________ which has pressures associated with it.
A) Circulating pump
B) Water cooler
C) Air cooler
D) Temperature gauge

A

A) Circulating pump

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

The normal supply pressure of the compressed air used for starting the engine is at about:
A) 2500 kPa (362.6psi)
B) 1500 kPa (217.6psi)
C) 2000 kPa (290.1psi)
D) 1250 kPa (181.3psi)

A

C) 2000 kPa (290.1psi)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

The most common starting method on large diesel engines used as drivers for auxiliary generator sets is:
A) Gas or steam turbine auxiliary shaft starting
B) Electric motor starting
C) Compressed air motor starting
D) Compressed air to cylinder starting
E) Exciter generator reverse starting

A

D) Compressed air to cylinder starting

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

To be synchronized with an electrical system an alternator set must have identical:
A) Frequency, voltage, and phase
B) Current, voltage, and phase
C) Frequency, current, and voltage
D) Frequency, phase and current
E) Frequency, voltage and current

A

A) Frequency, voltage, and phase

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

The name of the panel that allows an internal combustion engine generator set to automatically generate power into the grid is called a/an:
A) A motor/generator control panel
B) An electrical panel
C) A metering usage panel
D) A remote starting panel
E) A synchronizing panel

A

E) A synchronizing panel

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Standby generation must be:
A) Able to supply 60% load
B) At lease 50% available
C) Maintained ready to be started at any time
D) Used for spare parts
E) Only able to be used when power is overpriced

A

C) Maintained ready to be started at any time

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

An indicator of the efficiency of a diesel engine is:
A) Jacket water temperature
B) Lube oil pressure
C) Lube oil level
D) Cylinder exhaust temperature
E) Jacket water level

A

D) Cylinder exhaust temperature

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Standby generator sets require adequate:
A) Gas pressure, heating supply, lighting, and fan pressure
B) Refrigerant, water pressure, voltage, and steam pressure
C) Domestic water flow, hot water temp, bus load, and chiller load
D) Condenser water, air pressure, pH, and biocide level
E) Air, fuel, coolant, and lubricating oil

A

E) Air, fuel, coolant, and lubricating oil

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Which of the following is not a starting method for IC Gen-sets?
A) Compressed air to cylinder starting
B) Manual crank
C) Electric
D) Compressed air starting motor

A

B) Manual crank

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Temperatures are very important, and sometimes the cooling system includes a ________ which has pressures associated with it.
A) Temperature gauge
B) Water cooler
C) Air cooler
D) Cooling tower
E) Circulating pump

A

E) Circulating pump

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

The facilities alternator output must be the same as that of the utilities system relative to which of the following?
A) The wattage on each must be the same
B) The amperage on each must be the same
C) The impedance on each must be the same
D) The voltage on each must be the same
E) The resistance on each must be the same

A

D) The voltage on each must be the same

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Proper routine pre-start and operational checks may include all of the following except the:
A) Lubrication system
B) Machine exhaust temperatures
C) Atmospheric weather conditions
D) Start-up energy used
E) Cooling system

A

C) Atmospheric weather conditions

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

An electric starter rotates an internal combustion engine via a ring gear on the ___________.
A) Governor
B) Flywheel
C) Crankshaft
D) Reducing gear
E) Driveshaft

A

B) Flywheel

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

The normal supply pressure of the compressed air used for starting the engine is at about:
A) 3000kPa (435.1psi)
B) 1500kPa (217.5psi)
C) 2000kPa (290.1psi)
D) 2500kPa (362.6psi)
E) 1250kPa (181.3psi)

A

C). 2000kPa (290.1psi)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

The facilities alternator output must be the same as that of the utilities system relative to which of the following:
A) The wattage on each must be the same
B) The resistance on each must be the same
C) The amperage on each must be the same
D) The frequencies must be the same
E) The impedance on each must be the same

A

D) The frequencies must be the same

17
Q

If compressed air is used to start an IC gen-set, the _________ is a critical issue.
A) The battery voltage
B) Shaft temperature
C) Cylinder pressure
D) Speed of rotation

A

C) Cylinder pressure

18
Q

Larger engines incorporate a system whereby compressed air is directed _______ in order to cause engine rotation.
A) To the motor crank
B) To the turbine
C) On to the flywheel
D) To the starter motor
E) Onto the top of the piston

A

E) Onto the top of the piston

19
Q

An electric starter motor on an internal combustion engine is usually supplied with _________ volt DC power.
A) 12
B) 6
C) 24
D) 32
E) 110

A

A) 12