Which of the following are the distinct classes of refrigeration controls?
A) Operating or primary controls
B) Actuating or secondary controls
C) Limiting and safety controls
D) All of the above
D) All of the above
In the event of a low oil pressure condition, the oil pressure failure switch will:
A) Open the recycle valve to take the load off the compressor
B) Stop the flow of refrigerant to the system
C) Shut down the compressor
D) Sound an audible alarm
C) Shut down the compressor
CSA B52 Mechanical Refrigeration Code requires that all refrigeration systems,except listed and approved factory-sealed systems containing less than _________ of Group A1 refrigerant, and operating above atmosphere pressure, shall be equipped with a pressure limiting device.
A) 10kg (22lb)
B) 5kg (11lb)
C) 15kg (33.1lb)
D) 20kg (44.1lb)
A) 10kg (22lb)
Oil pressure failure switches are used to:
A) Keep the oil pressure at a level where the oil will not freeze
B) Keep oil from freezing at low pressure
C) Shutdown the compressor when the oil pressure drops below the minimum
D) Separate refrigerant dissolved in the oil from the lubricant
E) Prevent compressor start-up if the oil heater fails
C) Shutdown the compressor when the oil pressure drops below the minimum
Which of the following statements about flow switches is false?
A) They can be used to close flow indicator circuits
B) They are used as lockout switches when flow is insufficient
C) They are operated by the force exerted on a flexible vane immersed in the liquid flowing in the line
D) They can only be used to regulate liquid flow, not air flow
E) They are used on chilled water
D) They can only be used regulate liquid flow, not air flow
The maximum setting of a pressure limiting device on the high side of a refrigeration system must not exceed what percentage of the high side design pressure?
A) 100%
B) 75%
C) 80%
D) 90%
E) 50%
D) 90%
Which of the following actuating control valves is electromagnetically operated?
A) Thermostat valve
B) Evaporator pressure regulating valve
C) Solenoid valve
D) Condenser cooling water regulating valve
E) Fluid expansion regulator valve
C) Solenoid valve
The safety control which uses a current transformer with a resistor in the motor circuit is known as the:
A) High oil temperature cutout
B) Motor overload protection
C) Solenoid valve
D) Low oil sump temperature protection
E) High motor temperature cutout
B) Motor overload protection
A bimetallic element converts temperature changes to mechanical motion by having metals with different:
A) Coefficients of thermal conductivity
B) Rates of temperature change
C) Temperatures
D) Coefficients of linear expansion
E) Electron velocities
D) Coefficients of linear expansion
Operating or primary controls are used to:
A) Regulate the refrigeration system output when the operating limits are reached
B) Control the operation of cooling water
C) Regulate the refrigeration system output when the system limits are exceeded
D) Indirectly control changes in operation
E) Protect the system from operation beyond set limits
A) Regulate the refrigeration system output when the operating limits are reached
Expansion valves:
A) Will expand the liquid to the receiver
B) Relieve high pressure in the receiver
C) Are used to change the refrigeration system
D) Regulate the liquid refrigerant flow to the evaporator
E) Isolate the compressor from the condenser
D) Regulate the liquid refrigerant flow to the evaporator
Limiting or safety controls are used to:
A) Protect the system from operation beyond set limits
B) Indirectly control changes in operation
C) Regulate the refrigeration system output when the system limits are reached
D) Control the operation of cooling water
E) Regulate the refrigeration system output when the system limits are exceeded
A) Protect the system from operation beyond set limits
The operating control which uses a bimetal element is a:
A) Pressure actuated control
B) Solenoid actuated control
C) Fluid expansion actuating control
D) Humidity actuated control
E) Temperature actuated control
E) Temperature actuated control
Flow switches are used on chilled water and cooling water lines and air ducts are used as ___________ switches.
A) Safety lockout
B) Evaporator level control
C) Condenser pressure control
D) Over pressure lockout
E) Low temperature lockout
A) Safety lockout
The operation of the compressor (starting, stopping, and unloading) may be accomplished by a ________ type of actuated control.
A) Mass
B) Level
C) Density
D) Volume humidity
E) Pressure
E) Pressure