A705.1 Elevator Emergencies/Rescue (05-01-2013) Flashcards
[A705.1 Elevator Emergencies/Rescue]
What are the 2 types of elevators?
- Electric traction
- Hydraulic
[A705.1 Elevator Emergencies/Rescue]
This type of elevator consists of an elevator car suspended by cables and a counter-weight:
Electric traction
[A705.1 Elevator Emergencies/Rescue]
This type of elevator is hoisted on top of a piston ram, and is typically shorter with spans of ___ stories or less:
- Hydraulic
- 6 stories or less
[A705.1 Elevator Emergencies/Rescue]
What is AFD’s response to elevator emergencies?
Closest engine and aerial (Code 1)
[A705.1 Elevator Emergencies/Rescue]
When an elevator emergency consists of a passenger or passengers stuck in a stalled elevator with no other type of emergency, AFD shall:
Only attempt rescue through normal operation or forcible entry that does not cause damage
[A705.1 Elevator Emergencies/Rescue]
Any time there are reports of persons stuck in an elevator, this person should be requested immediately by the building management or alarm company?
An elevator mechanic
[A705.1 Elevator Emergencies/Rescue]
The first action for AFD at an elevator emergency is to:
Determine the location of the stalled elevator car
[A705.1 Elevator Emergencies/Rescue]
Elevators with “blind shafts” where there may be floors with no doors accessing the elevators are sometimes referred to as:
Express elevators
[A705.1 Elevator Emergencies/Rescue]
Who should request an elevator mechanic immediately on all reports of persons stuck in an elevator?
Building management or the alarm company
[A705.1 Elevator Emergencies/Rescue]
How should you establish communications with trapped passengers (2)?
- Using plug-in phones through the fire control room
- Yelling through the hoistway doors
[A705.1 Elevator Emergencies/Rescue]
How can you determine the location of the elevator car (2 ways)?
- By looking at the indicator in the elevator lobby
- By looking at the elevator status in the Fire Control Room
[A705.1 Elevator Emergencies/Rescue]
What are the (3) different ways to try to recall the elevators to the lobby through normal elevator operation?
- By using the key from the Fire Control Room or Knox box and putting the Fire Fighter Controls into phase 1
- Have the passengers inside the car simultaneously hold down the floor and door open buttons.
- Send a team of firefighters to the mechanical room and shut off power for 30 seconds to reset system
[A705.1 Elevator Emergencies/Rescue]
If normal elevation operation were not successful, what may be attempted?
Forcible entry without damage
[A705.1 Elevator Emergencies/Rescue]
When attempting to open the hoistway doors with an elevator key, the following (3) steps should be followed:
- Turn off power at main disconnect
- Instruct passengers to attempt to slide doors open
- Attempt to open with elevator key
[A705.1 Elevator Emergencies/Rescue]
The elevator key hole is located:
At the upper side on either side of the doors