A402.1 WUI Firefighting Operations (09/01/2014) Flashcards
[A402.1 WUI Firefighting Operations]
A WUI task force will be called by:
On scene resources and not as an initial response
[A402.1 WUI Firefighting Operations]
What has the Austin Fire Department adopted for wildland fire management?
The Cohesive National Strategy
[A402.1 WUI Firefighting Operations]
The Cohesive National Strategy includes public education promoting hardened homes through:
Fire-Adapted Communities and Firewise programs
[A402.1 WUI Firefighting Operations]
As well as public education, the Cohesive National Strategy involves what other 2 things:
- Fuels management programs
- Improved response protocols
[A402.1 WUI Firefighting Operations]
WUI response needs to operate as:
A component of the overall incident rather than a separate incident
[A402.1 WUI Firefighting Operations]
When dispatched to a wildfire incident, companies should check the incident call text on the MDC for a possible WUI Task Force assignment and related info such as these 3:
- Response location
- Task Force Leader
- Assigned radio channel
[A402.1 WUI Firefighting Operations]
What mode of fire attack will WUI Task Forces normally operate?
Defensive mode
[A402.1 WUI Firefighting Operations]
An offensive attack of a structure should only be considered after:
Structural triage of all threatened exposures has been completed and a risk/benefit analysis has been performed
[A402.1 WUI Firefighting Operations]
For all out of area responses, task force units will await the arrival of the Task Force Leader, and respond together as:
A unit
[A402.1 WUI Firefighting Operations]
The objectives of ______ should be considered:
RECEO
[A402.1 WUI Firefighting Operations]
If extreme fire behavior or a large fire front is evident and quickly approaching structures, these may be the only (2) tactics to perform:
- Rescue
- Evacuation
[A402.1 WUI Firefighting Operations]
What (3) important factors need to be included in a WUI size-up?
- Fire behavior
- Composition and condition of the structure itself
- The area surrounding the structure (Defensible space)
[A402.1 WUI Firefighting Operations]
What part of a house is the most vulnerable to fire spread when evaluating a structure?
The roof
[A402.1 WUI Firefighting Operations]
What is the general rule when determining the defensible space?
30 feet from the structure to flammable brush and trees
[A402.1 WUI Firefighting Operations]
What 4 structural triage levels are listed in the IRPG?
- Defensible - Stand-alone
- Defensible - Prep and hold
- Non-Defensible - Prep and Leave
- Non-Defensible - Rescue Drive-by
[A402.1 WUI Firefighting Operations]
What is the determining factor for Defensible - Stand-alone?
Safety zone present
[A402.1 WUI Firefighting Operations]
What is the determining factor for Defensible - Prep and hold?
Safety zone present